Fuel Conversion Kit
Instructions
for Intrepid Direct Vent Gas Stove
Kits:
Natural to LP: 20012921
LP to Natural: 20012910
WARNING!
The installation of this conversion kit must only be undertaken by a qualified gas appliance installer.
This kit is designed for conversion of the Intrepid Direct Vent Gas Stove Models INDVR Series.
Tools required: 5/32” (4 mm) Allen wrench, 3/8” and 1/2” open end wrenches, needlenose pliers.
Kit contents: Pilot orifice, injector orifice, conversion label.
Conversion Precautions
Allow unit to cool completely before beginning conver- sion. Before proceeding, turn control knob on valve to OFF and turn gas supply to OFF. Turn OFF any electric- ity that may be going to the appliance.
Conversion Procedure
1.Remove stove front. Lift stove front up and then swing bottom out and away to disengage from the stove body. (Fig. 1)
2.Undo the right and left latches at the top of the glass frame. (Fig. 2)
3.Pull the top edge of the glass and frame assembly away from the firebox face. Place the assembly out of the way on a flat, padded surface such as a coun- ter protected by a towel.
4.Remove the logset from the firebox.
INTREPID
ST967
Fig. 1 Remove the stove front. (Top vent shown)
ST208
Fig. 2 Release the latches to remove the glass frame.
Valve Conversion
1.Turn control knob to the OFF position, and shut off the gas supply to the valve.
2.Allow the valve to cool to room temperature.
3.Remove the black protection cap by hand. (Fig. 3)
4.Insert a 5/32” or 4 mm Allen wrench into the hexago- nal
Figure 3 | Figure 4 |
|
� �
� �
� �
� �
20012973 7/07 Rev. 0