TROUBLESHOOTING

 

 

 

 

 

 

Symptom

Probable Cause

Solution

The upper part of the

If the input signal comes from a computer system,

Input separate sync signals for vertical sync (V)

video image bows or

is this a sync signal of composite sync (Cs) or G

and horizontal sync (H) signals

distorts

on sync type?

 

Remote control unit does

Are batteries installed correctly?

Match the polarities of batteries correctly, as

not work.

 

shown on the battery cartridge.

 

Are batteries exhausted?

Replace with new batteries.

 

Is there an obstructive object between the remote

Remove any shielding objects.

 

control unit and the remote sensor?

 

 

Is the remote control held too far from the sensor?

Use the remote control unit at a nearer point.

45

Page 46
Image 46
Vidikron 60 manual Symptom Probable Cause Solution