GATE OPERATOR INSTALLATION

Limit Switch Setup

STEP 8

A. Loosen the screws on the limit switch cams and position the cams to the desired locations. There are additional holes provided in case of a wide or tight angle of opening or closing.

B. Move the gate manually and ensure that the limit switch gets actuated at the desired open and closed position. The limit switch will click when engaged by the limit cam.

C.Retighten the screws on the limit switch holders once the proper position has been determined.

CAUTION – DO NOT OVERTIGHTEN SCREWS!

D.Run the unit 2 full cycles without interruption (from limit to limit) to execute a “Learn Cycle.”

E.Fine-tune the adjustment of the Limit Switch Cams.

Note: Leave cover off until after the installation of the control box and the electrical installation. Verify that the operator opens and closes to the desired position under power. Make any adjustments as necessary.

STEP 9

Replace the cover and secure it with screws provided after finishing final adjustments.

Additional Cam

Mounting Holes

Limit Switch

Tighten Clamping

Holder

Screw Securely

Position Cam

Before Adjusting

Cams

to Suit

 