Gate does not run – Motor Sensor indicator comes ON
Check all motor connections to be fully engaged. Refer to page 18 and 19.
Ensure that the motor connections are:
a)Properly connected;
b)Tight enough and;
c)Match color code. Refer to page 15.
Check that all motor cable connections, junctions and extensions are properly connected and
Check the 15 Amp fuse in the control board
Gate does not run – Motor Sensor indicator is OFF
Check all motor connections to be fully engaged. Refer to 15.
Check that limit switches are connected to the common and the normally close position refer to page 15.
Check that the stop command is not active. Refer to page 8 and 25
Check that the UL command (photo beam and/or edge sensor) is not active. Refer to page 6, 7 and 22.
Check that the vehicular loop detectors are working properly. Refer to page 20, 21 and 22.
Check that the radio command is not active. Refer to page 23.
Ensure that you external accessories are working properly.
Check the 4 Amps fuse in the control board
Ensure that you power cables are adequate in voltage and properly connected. Refer to page 17.
Gate does not run – Power failure
Check the 15 Amp battery fuse. | Check the battery connections | Check the voltage of the |
Refer to page 16 | and cables. | battery. |
Gate does not run – Obstruction sensor ON and audio alarm is SOUNDING
Ensure that the gate path is | Note: To stop the audio alarm, | If necessary, adjust the trim pot |
clear of obstructions. | use the stop command. Refer | for the obstruction sensor. |
| to page 8 and 25. | Refer to page 26 |
Gate runs, stops and reverse momentarily – Obstruction sensor ON and audio alarm OFF
Ensure that the gate path is clear of obstructions.
Check for proper functionality and lubrication of the gate and hardware (hinges and the like).
Adjust the trim pot of the obstruction sensor. Refer to page 26.
Gate ignores the limit switches
Check that the open limit switch and close limit switch are in the corresponding place. Refer to page 15.
Check that all motor cable connections, junctions and extensions are properly connected and
Ensure that the motor cable is away from sources of electrical interference, such as
a)Electric motors
b)Electric fences
c)Power lines
Check that the limit switch is not faulty
Check that wires to the limit switch are not shorted.
Note: To minimize effects cause by electrical interference use twisted pairs of cables with the shield grounded.
9 |
|
| TECHNICAL SUPPORT 1 800 908 0884 Se habla Español | 31 |