Vivotek FD7141(V) manual Query Status of the Digital Output, di3=<state>\r\n, Method: GET/POST

Models: FD7141(V)

1 129
Download 129 pages 11.02 Kb
Page 120
Image 120
[di0=<state>]\r\n

VIVOTEK - A Leading Provider of Multimedia Communication Solutions

http://<servername>/cgi-bin/dido/getdi.cgi?[di0][&di1][&di2][&di3]

If no parameter is specified, all of the digital input statuses will be returned.

Return:

HTTP/1.0 200 OK\r\n Content-Type: text/plain\r\n Content-Length: <length>\r\n \r\n

[di0=<state>]\r\n

[di1=<state>]\r\n

[di2=<state>]\r\n

[di3=<state>]\r\n

where <state> can be 0 or 1.

Example: Query the status of digital input 1 .

Request:

http://myserver/cgi-bin/dido/getdi.cgi?di1

Response:

HTTP/1.0 200 OK\r\n

Content-Type: text/plain\r\n

Content-Length: 7\r\n

\r\n

di1=1\r\n

Query Status of the Digital Output

Note: This request requires Viewer privileges.

Method: GET/POST

Syntax:

http://<servername>/cgi-bin/dido/getdo.cgi?[do0][&do1][&do2][&do3]

If no parameter is specified, all the digital output statuses will be returned.

Return:

HTTP/1.0 200 OK\r\n

Content-Type: text/plain\r\n

Content-Length: <length>\r\n

120 - User's Manual

Page 120
Image 120
Vivotek FD7141(V) Query Status of the Digital Output, di0=<state>\r\n di1=<state>\r\n di2=<state>\r\n, di3=<state>\r\n