dido,

camctrl,

camera’s parameters except some privilege and

 

operator

 

network options

 

 

 

6 [admin]

anonymous, viewer,

Administrator’s access right can fully control the

 

dido,

camctrl,

camera’s operation.

 

operator, admin

 

 

 

 

 

7

N/A

 

Internal parameters. Unable to be changed by

 

 

 

any external interface.

 

 

 

 

Get server parameter values

Note: The access right depends on the URL directory.

Method: GET/POST

Syntax:

http://<servername>/cgi-bin/anonymous/getparam.cgi?[<parameter>] [&<parameter>…]

http://<servername>/cgi-bin/viewer/getparam.cgi?[<parameter>] [&<parameter>…]

http://<servername>/cgi-bin/operator/getparam.cgi?[<parameter>] [&<parameter>…]

http://<servername>/cgi-bin/admin/getparam.cgi?[<parameter>] [&<parameter>…]

where the <parameter> should be <group>[_<name>] or <group>[.<name>] If you do not specify the any parameters, all the parameters on the server will be returned. If you specify only <group>, the parameters of related group will be returned.

When query parameter values, the current parameter value are returned. Successful control request returns paramter pairs as follows.

Return:

- 67 -

www.vivotek.com

T: 886-2-82455282

F: 886-2-82455532

Page 68
Image 68
Vivotek IP7152, IP7151 manual Get server parameter values, Method GET/POST