hostname

<text

string

shorter

host name of server

(r/w)

than 15 characters>

 

 

 

 

 

 

 

 

ledoff

0

 

 

 

Do not turn of the led indicator

(r/w)

 

 

 

 

 

1

 

 

 

Turn off the led indicator

 

 

 

 

 

 

resetdo

0

 

 

 

Do not turn on automatic DO restoration

(r/w)

 

 

 

 

 

1

 

 

 

Turn on automatic DO restoration

 

 

 

 

 

 

delayresetdo

1~999

 

 

 

Setup automatic DO restoration time

(r/w)

 

 

 

 

 

 

 

 

 

 

date

<yyyy/mm/dd>

 

 

year, month and date separated by slash.

(r/w)

 

 

 

 

 

<keep>

 

 

 

keep date unchanged

 

 

 

 

 

 

 

<auto>

 

 

 

Using NTP to sync date/time

 

 

 

 

 

automatically

 

 

 

 

 

time

<hh:mm:ss>

 

 

hour, minute and second separated by

(r/w)

 

 

 

 

colon.

 

 

 

 

 

 

 

<keep>

 

 

 

keep date unchanged

 

 

 

 

 

 

 

<auto>

 

 

 

Using NTP to sync date/time

 

 

 

 

 

automatically

 

 

 

 

 

ntp

<domain name

or

IP

NTP server

(r/w)

address>

 

 

 

 

 

 

 

 

timezone

-12 ~ 12

 

 

time zone, 8 means GMT +8:00

(r/w)

 

 

 

 

 

 

 

 

 

 

updateinterval

0 ~ 2147483

 

 

0 to Disable automatic time adjustment,

(r/w)

 

 

 

 

otherwise, it means the seconds

 

 

 

 

 

between NTP automatic update interval.

 

 

 

 

 

serialnumber

<mac address>

 

 

12 characters mac address without

(r)

 

 

 

 

hyphen connected

 

 

 

 

 

firmwareversion

<text

string

shorter

The version of firmware, including

(r)

than 39 characters>

 

model, company, and version number

 

 

 

 

 

 

restore

0

 

 

 

Restore the system parameters to

(w)

 

 

 

 

default value. The value will be valid

 

 

 

 

 

after restart the server.

 

 

 

 

 

restart

0 ~ 65535

 

 

Restart the server after <value>

 

 

 

 

 

 

- 69 -