Vulcan-Hart 3GR45DF ML-136427, 2GR45DF ML-136424 manual Draining The Tank, Boil Out Procedure

Models: 1GR65CF ML-136792 1GR65C ML-136415 1GR65D ML-136412 1GR45C ML-136414 1GR45CF ML-136791 1GR85C ML-136416 1GR45D ML-136411 1GR45DF ML-136778 1GR65DF ML-136789 1GR85DF ML-136790 1GR85CF ML-136793 1GR85D ML-136413 2GR45CF ML-136431 2GR45DF ML-136424 3GR45DF ML-136427

1 27
Download 27 pages 3.39 Kb
Page 15
Image 15
DRAINING THE TANK

GRDF / GRCF SERIES GAS FRYERS

DRAINING THE TANK

1.Turn off fryer.

2.Insert the drain extension into the drain valve. Tighten only hand tight.

3.Direct the drain spout into the container that you want to drain the shortening into.

4.Open the drain valve. The oil will drain into the container. When the container is full or the fryer tank is empty, close the drain valve. Repeat this step until the fryer is empty. Remove the drain extension and place it back into the provided holder.

5.It is recommended to now Boil Out your fry tank. Follow the Boil Out procedure. Then perform the weekly clean-out as described under CLEANING.

6.Once tank is completely empty, boiled out and cleaned, add new shortening. Turn on the power switch to begin heating the oil to desired temperature.

BOIL OUT PROCEDURE

Weekly or when oil is replaced:

1.Drain the tank as described under FILTERING THE OIL and instead of replacing the shortening with new oil fill with water

2.Close the drain valve and fill tank with water. Use recommended Vulcan’s Boil-Out solid degreaser low foaming cleaner tablets part number 956812-1 which can be ordered from your local dealer. Follow the instructions on the side of the package.

BOIL OUT PROCEDURE Do not use chlorine or sulfate/sulfide cleaners.

3.Solution level must be between the MIN and MAX levels on the fryer tank.

4.After pressing the TEMP button for the second time confirming that the boil out solution level is correct the gas burners will begin to heat the water solution. The fryer controls will be able to sense that there is a water mix solution vs. oil and will automatically set the correct temperature. There is NO need to change the set temperature from the last set operating temperature. Allow solution to simmer for about 15 to 20 minutes. Use a tank brush to clean the sides, back, front, and heat exchanger tubes.

5.With the drain extension tightened into the drain valve, drain and discard the cleaning solution from the tank.

6.Close the drain valve and refill the tank with water. Add 1 cup (1/4 L) of vinegar to neutralize alkaline left by the cleaner. Solution level must be between the MIN and MAX level on the fryer tank. Press the TEMP button to confirm the vinegar level is correct.

VULCAN-HART

F-32933 Rev. G (May 2009)

-15-

Page 15
Image 15
Vulcan-Hart 3GR45DF ML-136427, 2GR45DF ML-136424 Draining The Tank, Boil Out Procedure, Weekly or when oil is replaced