REC ONLY: Only alarm recording will start and moni- tors will keep displaying the current sequence/spot images.

Note: You cannot recover alarm-related operations from system controllers when REC ONLY is selected.

OFF: An alarm input is not accepted via the ALARM port.

The factory default setting is ON.

Each alarm input's polarity is configurable in the submenu. Set ALARM PORT to ON or REC ONLY, and press the CAM (SET) button.

440 ALARM INPUT (ALARM PORT) will appear on the moni- tor.

440 ALARM INPUT(ALARM PORT)

SWITCHER=SLAVE1(1 of 5)

1

NORMALLY OPEN

9

NORMALLY OPEN

2

NORMALLY CLOSE

10

NORMALLY OPEN

3

NORMALLY OPEN

11

NORMALLY OPEN

4

NORMALLY OPEN

12

NORMALLY OPEN

5

NORMALLY CLOSE

13

NORMALLY OPEN

6

NORMALLY OPEN

14

NORMALLY OPEN

7

NORMALLY OPEN

15

NORMALLY OPEN

8

NORMALLY OPEN

16

TIME ADJUST

Move the cursor and press the CAM (SET) button to go into the menu.

SWITCHER: Select a unit (SLAVE1 to 4 and MASTER*) to configure the parameters.

* In normal connection, only MASTER is displayed.

After designating the unit, select the desired polarity for ALARM 1 to 16.

NORMALLY OPEN: Normally Open contact is activat- ed for the alarm input signal.

NORMALLY CLOSE: Normally Close contact is activat- ed for the alarm input signal.

TIME ADJUST: This polarity enables the input of the time adjusting signal.

The factory default setting is N. O.

Note: In the master-slave connection, time setting of every unit can be synchronized when the time adjusting signal is input to any unit.

450 SERIAL PORT

This stands for that an alarm input is accepted via the SERI- AL port.

ON: The alarm-associated sequence/spot image is dis- played on a monitor, and alarm recording will start (if a recorder is connected to the unit.)

REC ONLY: Only alarm recording will start and moni- tors will keep displaying the current sequence/spot images.

Note: You cannot recover alarm-related operations from system controllers when REC ONLY is selected.

OFF: An alarm input is not accepted via the SERIAL port.

The factory default setting is ON.

460 MUX MOTION DET MUX

This stands for that the unit’s motion detector is activated when a camera detects the brightness-level change and transmit an alarm signal.

ON: The alarm-associated sequence/spot image is dis- played on a monitor, and alarm recording will start (if a recorder is connected to the unit.)

REC ONLY: Only alarm recording will start and moni- tors will keep displaying the current sequence/spot images.

Notes:

If the Multiplexer board is not installed in the unit, you cannot enter the submenu of 460 MUX MOTION DET.

You cannot recover alarm-related operations from system controllers when REC ONLY is selected.

OFF: An alarm input is not accepted by the motion detector.

To configure where to activate the motion detector, set MUX MOTION DET to ON or REC ONLY, and press the CAM (SET) button. The live image will be displayed.

Up to 4 motion-detection areas are configured for each camera channel.

Note: Black image will be displayed on the monitor if the currently selected channel has no camera con- nection.

A “+” mark appears at the center of the monitor.

Logical camera number and sensitivity

C01 LOW

+ Mark

The following is the setting procedure.

69

Page 69
Image 69
Panasonic WJ-SX150A manual Serial Port, MUX Motion DET MUX, Following is the setting procedure