ALARM CONTROL

ALARM CONTROL

Alarm Mode

When alarm (sensor) is accepted, the matrix switcher's operation mode changes to the alarm mode. Then, the sys- tem operates as follows:

The camera image (alarm image) appears on the moni- tor.

In the factory default setting, the alarm inputs 1 to 16 are associated with the same-numbered camera input connectors. All the video output signals are sent to Monitor 1. For example, when the alarm (sensor) con- nected to the alarm input 1 becomes active, the camera input connector 1’s image appears on Monitor 1.

"ALARMnn" appears on the monitor. (nn is the alarm number).

ALARM01

Alarm output signals are supplied from Alarm Output 1 to 4 (#10, 11, 23 and 24) of the ALARM port (25-pin D- sub connector) at the rear panel. Alarm Output 1 to 4 is associated with MONITOR OUT 1 to 4. For example, when an alarm input signal is activated on MONITOR OUT 1, the unit supplies an alarm output signal from Alarm Output 1.

The monitor and alarm number will appear on the LED display of system controllers. At the same time, the alarm indicator will blink, the monitor indicator will light up, and the camera indicator will go out.

There are two operation mode when more than one alarm signal has been accepted by the unit that is assigned to the same monitor.

Sequence mode: An alarm operation is replaced by another one after the dwell time ends.

Hold mode: An initial alarm operation is continued even after another alarm input is accepted.

Notes:

The association of the alarm inputs with cameras and monitors are changeable in SETUP MENU or WJ- SX150A Administrator Console. (Refer to pp. 67 and 68/ p. 89.)

Alarm input will be automatically reset in 30 seconds. The auto-recovery time is configurable through SETUP MENU or WJ-SX150A Administrator Console.

Operation during an Alarm Mode

While an alarm mode is active, the following are available from the system controller:

Operating the camera with the alarm input (ACK)

Resetting the alarm (RESET/ALL RESET)

Suspending the alarm (ALM SUSPENDED)

Operation of an Alarm-related Camera (ACK)

You can operate the camera with the alarm input as follows:

ACK

RESET

 

 

 

 

SUSPEND

ALL RESET

 

 

 

 

GROUP SEQ

TOUR SEQ

T&D

CAM ID

EVENT

 

REW/FF

STILL

AUX1 OFF

AUX1 ON

 

PREV

NEXT

MON STATUS

ALL

 

ACK

STEP

 

EL-ZOOM

AUX2 OFF

AUX2 ON

 

PAUSE

ALM H

VLD H

SYS S

 

PLAY

PAUSE

SEQUENCE

DEF OFF

DEF ON

 

OSD

 

MON (ESC)

 

CAM (SET)

 

 

SHIFT

MON LOCK

MULTI SCREEN SEL

WIPER

 

1.Select a monitor which displays "ALARM".

2.Press the ACK button.

"ACK" will appear on the monitor with an alarm input. The camera with an alarm input will become operable.

3.Operate camera with the system controller. Pan/Tilt, zoom, focus, and iris are available.

When selecting another monitor, "ACK" will disappear from the display. The matrix switcher system will return to the alarm mode.