Panasonic WJ-SX150A manual Alarm Event, Sensitivity MUX, Mon Monitor, LCN/Tour, How to Display

Models: WJ-SX150A

1 176
Download 176 pages 28.71 Kb
Page 89
Image 89
●Sensitivity MUX

MUX MOTION DET MUX : This stands for that the unit’s motion detector is activated. When a camera detects the brightness-level change and transmit an alarm signal, the alarm-associated sequence/spot image is displayed on a monitor, and alarm record- ing will start (if a recorder is connected to the unit).

ON: The alarm-associated sequence/spot image is dis- played on a monitor, and alarm recording will start (if a recorder is connected to the unit.)

REC ONLY: Only an alarm recording will start and monitors will keep displaying the current sequence/spot images.

Note: You cannot recover alarm-related operations from system controllers when REC ONLY is selected.

OFF: An alarm input is not accepted by the motion detector.

The factory default setting is OFF.

Sensitivity: When you click this button, the Sensitivity window will appear.

Sensitivity MUX

When you press this button, the Sensitivity window will appear. In this window, you can configure the sensitivity level of the Multiplexer motion detector on each camera channel.

Auto Reset Time

Select the time to reset the alarm input.

The selectable time: OFF (not resetting the alarm), 10, 20, 30, 40, 50, 60, 120 or 180 (seconds)

The factory default setting is 30 sec.

•Auto Reset Time (Save Exit) button

Saves the configuration and closes the Alarm Mode win- dow.

■Alarm Event (Cancel Exit) button

Cancels the configuration and closes the Alarm Mode win- dow.

Alarm Event

This window configures the details of operation parameters when an alarm signal is input: the monitor and mode to dis- play the alarm image, and the preset position of the cam- era. Up to 99 alarm inputs are configurable.

OFF: The motion detector is not activated on the cam- era channel.

LOW: The sensitivity level is low.

MID: The sensitivity level is medium.

HIGH: The sensitivity level is high.

The factory default setting of all the channels is LOW.

How to Display

To display this window, click on the Mon (Monitor) (Alarm Event) but- ton in the main window (p. 80).

Parameters

Mon (Monitor)

Select the monitor to display the alarm image.

LCN/Tour

Select the spot camera number or the tour sequence num- ber.

LCN: Select this to display a spot picture.

Tour: Select this to execute a tour sequence.

Num: Select a LCN or Tour number. For LCN, 1 to 99 is selectable. For Tour, 1 to 32 is selectable.

Pre (Preset Position Number)

Select the preset position of the camera when selecting the spot camera number in Spot/Tour. Position 1 to 64 is selec- table for Pre. When the camera is not equipped with the preset position function, select "--".

89

Page 89
Image 89
Panasonic WJ-SX150A manual Alarm Event, Sensitivity MUX, Mon Monitor, LCN/Tour, How to Display, Parameters, Auto Reset Time