●Parameters
Move the joystick to move the cursor.
Press the NEXT or PREV button to select the desired para- meters.
Press the numeric button(s) to enter a number.
TOUR NO: Press the NEXT or PREV button to select the tour number. Or press the numeric button(s) to enter a number.
STEP: This stands for a tour sequence step.
LCN: This stands for a logical camera number. 01 to 99 or “-
The factory default setting is assigned to each step in numerical order (STEP 1 = LCN 1, STEP 2 = LCN 2, STEP 3 = LCN 3, STEP 4 = LCN 4, STEP 5 = LCN 5…)
PRE: This stands for a camera’s preset position num- ber. 1 to 64 or "-
The factory default setting is "-
DWELL: This stands for the dwell time. 1 second to 30 seconds is selectable. To delete the sequence step, select “-
The factory default setting is 2S for each step.
After the configuration, press the MON (ESC) button. The monitor display will return to the previous menu.
After all the configurations, press the SETUP button while holding down the SHIFT button. The configuration will be updated when closing SETUP MENU.
Notes:
•A preset position number is available only when a com- bination camera is selected for CAM.
•The available preset position numbers differ among cameras. Refer to each camera's operating instruc- tions.
■ALARM SETUP
400 ALARM
410 ALARM MODE | SEQUENCE | / DWELL 2sec |
420ALARM EVENT ALARM INPUT
430 | CAMERA | OFF |
440 | ALARM PORT | ONO |
450 | SERIAL PORT | ON |
460 | MUX MOTION DET | OFFO |
●How to Display
To display this menu on the monitor, move the cursor to 400 ALARM in SETUP MENU by moving the joystick to ▼ or ▲. Then, press the CAM (SET) button. The submenu appears on the monitor.
●Parameters
Move the joystick to move the cursor.
Press the NEXT or PREV button to select the desired para- meters.
Press the numeric button(s) to enter a number.
•ALARM MODE
You can select an operation mode when alarm input signals are accepted by the unit.
Notes:
•The alarm mode is activated when alarm input signals are assigned to the same monitor through 420 ALARM EVENT or the Alarm Event (refer to pp. 67 and 68/
pp. 89 and 90) window.
•While alarm is activated, you cannot operate the func- tions related to the Multiplexer board.
SEQUENCE: An alarm operation is replaced by anoth- er one after the dwell time (DWELL) ends.
HOLD: An initial alarm operation is continued even after another alarm input is accepted.
OFF: Select this when not using the alarm mode.
The factory default setting is SEQUENCE.
•DWELL
This stands for the dwell time of a sequence during an alarm mode.
1 to 30 seconds are selectable.
The factory default setting is 2 seconds.
•ALARM EVENT
This item is configurable in 420 ALARM EVENT. Move the cursor and press the CAM (SET) button. 420 ALARM EVENT will appear on the monitor.
420 ALARM | EVENT |
| 1 | of 10 | ||
ALM MON MODE | REC ALARM PORT |
| ||||
|
| LCN(PRE)/TOUR |
|
|
|
|
1 | 1 | LCN 01 / PRE01 R0 | MASTER / | 1 | ||
2 | 1 | LCN 02 / PRE01 R0 | MASTER / | 2 | ||
3 | 1 | LCN 03 / PRE01 R0 | MASTER / | 3 | ||
4 | 1 | LCN 04 / PRE01 R0 | MASTER / | 4 | ||
5 | 1 | LCN 05 / PRE01 R0 | MASTER / | 5 | ||
6 | 1 | LCN 06 / PRE01 R0 | MASTER / | 6 | ||
7 | 1 | LCN 07 / PRE01 R0 | MASTER / | 7 | ||
8 | 1 | LCN 08 / PRE01 R0 | MASTER / | 8 | ||
9 | 1 | LCN 09 / PRE01 R0 | MASTER / | 9 | ||
10 | 1 | LCN 10 / PRE01 R0 | MASTER / 10 | |||
|
| LCN:LOGICAL CAMERA | NUMBER |
|
| |
|
|
|
|
|
|
|
67