Panasonic WJ-SX150A manual Multiplexer Mux, CAM 01 to, How to Display, Parameters, Alarm

Models: WJ-SX150A

1 176
Download 176 pages 28.71 Kb
Page 77
Image 77
•CAM 01 to 16:

CAM 01 to 16:

These stand for an operator's camera operation coverage. The following are the parameters.

VIEW & CONTROL: The operator can display the cam- era image on the monitor and control panning/tilt- ing.

VIEW ONLY: The operator can display the camera image on the monitor, but cannot control the pan- ning/tilting.

PROHIBITED: The operator can neither display the camera image on the monitor nor control the pan- ning/tilting.

The following is the factory default setting of this menu.

OPERATOR NO.

ID

PASSWORD

LEVEL

PRIORITY

1

150

150

1

1

2

1

12345

1

2

3

100

100

1

3

4

101

101

1

4

5

102

102

2

5

6

103

103

3

6

CAM 1 to 16 = VIEW & CONTROL (for OPERATOR NO. 1 to 6)

Note: When you enter an invalid number, the parameter will return to the state before your numerical entry.

MULTIPLEXER MUX

900

MULTIPLEXER

 

 

SWITCHER=SLAVE1(1 of 5)

Ver..∗∗

 

VCR REC MODE

 

 

910

ALARM

EXT.

 

920

NORMAL

EXT.

 

930

DYNAMIC REC

OFF

 

940

DUMMY BLACK

ON

 

950

CAM SW LOSS

ON

 

 

 

 

 

 

 

 

 

900

MULTIPLEXER

 

 

SWITCHER=MASTER(5 of 5)

Ver..∗∗

 

VCR REC MODE

 

 

910

ALARM

---

 

920

NORMAL

---

 

930

DYNAMIC REC

---

 

940

DUMMY BLACK

---

 

950

CAM SW LOSS

---

 

 

 

 

 

How to Display

To display this menu on the monitor, move the cursor to 900 MULTIPLEXER in SETUP MENU by moving the joystick to D or C. Then, press the CAM (SET) button. The submenu appears on the monitor.

Parameters

Move the joystick to move the cursor.

Press the NEXT or PREV button to select the desired para- meters.

SWITCHER: Select a unit (SLAVE1 to 4 and MASTER*) to configure the parameters.

*In normal connection, only MASTER is displayed. Ver. . ∗∗: Firmware version of a Multiplexer board

ALARM

EXT.: Select this to gen-lock the unit with the recorder when an alarm is input to the unit.

002,004 to 128 (field): Select one of these alarm recording rates if the asynchronous unit is connect- ed to the unit.

The factory default setting is EXT.