●To Control a Recorder via the Network
The following is the description of the connection between a recorder and this unit to control the recorder via the net- work.
1.Set the recorder's unit address to a number 5 or larger . (Refer to the recorder's operating instructions.)
2.Connect the unit’s CAM OUT 1 to 16 connectors to the recorder’s VIDEO IN 1 to 16 connectors with a coaxial cable.
3.Connect the unit’s DATA HDR and DATA4 connectors to the recorder’s DATA port with a daisy chain connec- tion cable kit
(The control data and alarm signal will be output from the unit to the recorder.)
4.Select the recorder’s new unit address, which is set in Step 1, in 600 RECORDER (refer to p. 71 ) of SETUP MENU or the Recorder (refer to p. 97 ) window of WJ- SX150A Administrator Console.
5.Through a browser, set the unit address of an optional network board
6.Refer to p. 38, p. 40 and p. 41 for MONITOR OUT con- nection, MULTI SCREEN OUT connection, and EXT IN connection.
Monitor
Matrix Switcher | EXT IN | MONITOR |
| OUT | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| EXT IN |
| 3 | 1 |
|
|
|
| ALARM |
|
|
| SERIAL |
|
|
|
| (PLAY IN) |
|
|
|
|
|
|
|
|
|
|
| RS485(CAMERA) |
| CAMERA |
|
|
| |||
|
|
|
|
|
| DATA HDR DATA 4 | DATA 3 | DATA 2 | DATA 1 |
| SW IN |
|
|
| ||
|
|
|
| TERM |
| LINE |
|
|
|
| ||||||
|
|
|
|
|
|
|
| 2 | SELECT | 4 |
|
|
|
| ||
|
|
|
| OFF | ON |
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
| EXT OUT |
| 4 | 2 |
16 |
|
|
|
|
| PS•DATA |
| RS485(CAMERA) |
|
|
|
| (REC OUT) | 3 | MONITOR OUT |
|
15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 |
| 5 | 4 | 2 | 1 | ||
IN |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
OUT |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
16 | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 |
| 5 | 4 | 3 | 2 | 1 |
|
|
|
|
|
|
| CAMERA |
|
|
|
|
|
|
|
|
|
|
|
| DATA HDR | DATA4 |
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
| (PS·Data) |
|
|
|
|
|
|
Daisy Chain Connection Kit
MULTI SCREEN
OUTDATA
IN | EXT STORAGE | COPY |
|
| |
SPOT |
| DATA | 10/100 | ||
| SERIAL | ||||
OUT |
|
|
|
OUT |
|
| CONTROL |
|
| ALARM |
| MODE |
|
|
|
|
|
|
|
MULTI SCREEN OUT AUDIO | 14 | 12 | 11 | 9 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | ||||
16 | 15 | 13 | 10 | 8 | |||||||||||
IN |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
OUT |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
16 | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 |
|
|
|
|
|
|
| VIDEO |
|
|
|
|
|
|
|
|
Recorder* |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| LAN Cable |
|
HUB/Router
LAN**
*
**LAN : Local Area Network
Notes:
•You will need
•Select the PS·Data protocol for the DATA 4 setting. (Refer to p. 74 CAMERA/DATA1 - 4 PORT or p. 96 Data Port.) If the terminal mode is selected, you cannot con- trol the recorder.
•The recorder will not be operable if its unit address is set to 1/2/3/4.
•If the recorder's unit address in Step 1 and the recorder setting in Step 4 are different, the recorder will not be operable.
•In these connections, you cannot use a PS·Data system controller.
42