Panasonic WJ-SX150A Alarm Settings, Operator Settings, System Settings, Setup File Operation

Models: WJ-SX150A

1 176
Download 176 pages 28.71 Kb
Page 62
Image 62
●Alarm Settings

Alarm Settings

The operation parameters when an alarm is input to the unit are configurable.

Alarm mode: The operation mode activated along with an alarm input is configurable. Sequence mode or hold mode is selectable. Alarm mode can be set to OFF when not using it.

Alarm event: The sequence number or spot camera is selectable for the alarm event.

Alarm input (Alarm port): The alarm polarity (N. O. or N. C.) is assignable to each alarm input terminal.

It is also selectable whether to activate the recording and sequence/spot image monitoring when an alarm signal is input to the unit. Alarm recording without the sequence/spot image monitoring is also available.

Operator Settings

If you control this unit with a terminal-mode system con- troller, your operator information, controllable monitors and auto log-in/log-out will be registrable and configurable.

Operator registration: Up to 16 operators are available. ID and password for operator identification are config- urable. Level and priority can be assigned to each operator. Each camera's control coverage is also con- figurable.

Level table: Restriction level for each password is cus- tomizable.

Monitor select (Monitor selection): Controllable monitor can be assigned to each controller.

Auto login/logout (Auto log-in/log-out): Auto log-in/log- out is configurable for each controller.

Notes:

These settings (except Operator registration) are con- figurable only through WJ-SX150A Administrator Console. Operator registration is configurable through SETUP MENU and WJ-SX150A Administrator Console.

When you control the unit with a PS·Data system con- troller, the above settings will be invalid. Refer to the system controller's operating instructions.

System Settings

SETUP MENU can configure the clock (time and date), cable compensation and camera title.

Besides these settings, WJ-SX150A Administrator Console can select the data ports' baud rates.

Clock (Time and date): The unit's time and date are configurable.

Cable compensation: Cable compensation type is selectable depending on the distance between a cam- era and the unit. It is also possible to determine whether to send the VD2 timing pulse or control data with the camera output signals.

Camera title: Camera title is configurable to identify the camera images on the monitor. WJ-SX150A Administrator Console can configure the camera title including original characters.

Data port: Usually, the ports DATA 1 to 3 connect to the terminal-mode system controllers. RS-485 cameras will be connectable with the data port configurations through WJ-SX150A Administrator Console and SETUP MENU.

When you use the system controllers via the PS·Data protocol, you need to configure the DATA 4 port setting through SX150A Admin Console or SETUP MENU.

Recorder: The type and unit address of the recorder are configurable.

Multiplxer: The parameters of the recorder mode are configurable. You can set the alarm and normal record- ing rate. You can also activate/deactivate dynamic recording, dummy black, and "CAMSW LOSS Rn” indi- cation. (Rn is a recorder number.) MUX

Mux camera (Multiplexer) title: Camera titles which are displayed with multiscreen segments are configurable.

MUX

Setup File Operation

WJ-SX150A Administrator Console can send a configura- tion file from the PC to this unit. The utility can also send the file from the unit to the PC for configuration.

Put a file to SX150A: A configuration data is sent from the PC to the unit.

Get a configuration data from SX150A: A configuration data is sent from the unit to the PC.

Select setup data file: A configuration data is selected when sending it from the PC to the unit (or from the unit to the PC.)

Note: These settings are configurable only through WJ- SX150A Administrator Console.

WJ-SX150A Administrator Console Configuration

The PC-related settings are configurable.

Account Manager: WJ-SX150A Administrator Console operators are registrable and changeable.

Communication (Serial) port: PC's usable communica- tion port number and its baud rate (communication speed) are configurable.

62

Page 62
Image 62
Panasonic WJ-SX150A manual Alarm Settings, Operator Settings, System Settings, Setup File Operation