Vulcan-Hart EG260, EG160, EG60, EG36, EG48 GAS CONNECTIONS Cont, Testing The Gas Supply System

Models: EG48 EG36 EG60 EG260 EG160

1 35
Download 35 pages 54.75 Kb
Page 11
Image 11
GAS CONNECTIONS (Cont.)

GAS CONNECTIONS (Cont.)

NOTE: A leak limiter is supplied with every regulator to allow excess gas pressure to escape. Do not obstruct leak limiter on gas pressure regulator as obstruction may cause regulator to malfunction.

WARNING: PRIOR TO LIGHTING, CHECK ALL JOINTS IN THE GAS SUPPLY LINE FOR LEAKS. USE SOAP AND WATER SOLUTION. DO NOT USE AN OPEN FLAME.

After piping has been checked for leaks, all piping receiving gas should be fully purged to remove air.

TESTING THE GAS SUPPLY SYSTEM

IMPORTANT: When test pressures exceed 12 psig (3.45 kPa), the range and its individual shutoff valve must be disconnected from the gas supply piping system.

When test pressures are 12 psig (3.45 kPa) or less, the range must be isolated from the gas supply system by closing its individual manual shutoff valve.

ORIFICE SIZE REQUIREMENTS

FOR DIFFERENT ELEVATIONS

FOR RESTAURANT RANGE

 

 

OPEN TOP

HOT TOP

GRIDDLE

BRO/GRID

OVEN

 

 

 

 

 

(STD)

 

 

INPUT AT SEA LEVEL

 

 

 

 

 

 

17,500

20,000

15,000

10,000

30,000

 

PER BURNER (BTU’S)

5.124 kW

5.856 kW

4.392 kW

2.928 kW

8.784 kW

 

 

 

 

 

 

 

 

ORIFICE SIZE

NAT/PROP

NAT/PROP

NAT/PROP

NAT/PROP

NAT/PROP

 

 

 

 

 

 

 

 

SEA LEVEL

Drill

Drill

Drill

Drill

Drill

 

47/56

44/55

48/57

52/62

36/52

 

TO

 

mm

mm

mm

mm

mm

 

2000 FT

 

2.00/1.5

2.20/1.35

1.95/1.10

1.60/1.00

2.7/1.60

 

 

 

 

 

 

 

 

 

 

2000 FT

Drill

Drill

Drill

Drill

Drill

 

48/56

45/55

49/58

53/65

39/53

 

TO

 

mm

mm

mm

mm

mm

 

4000 FT

 

1.95/1.15

2.10/1.35

1.85/1.05

1.50/0.9

2.50/1.50

 

 

 

 

 

 

 

 

 

 

4000 FT

Drill

Drill

Drill

Drill

Drill

 

49/57

46/56

50/60

53/66

40/54

 

TO

 

mm

mm

mm

mm

mm

 

6000 FT

 

1.48/1.10

2.05/1.15

1.80/1.00

1.50/0.8

2.50/1.40

 

 

 

 

 

 

 

 

 

 

6000 FT

Drill

Drill

Drill

Drill

Drill

 

50/58

47/57

51/63

54/67

41/55

 

TO

 

mm

mm

mm

mm

mm

 

8000 FT

 

1.80/1.05

2.00/1.10

1.70/0.9

1.40/0.8

2.45/1.35

 

 

 

 

 

 

 

 

 

– 12 –

Page 11
Image 11
Vulcan-Hart EG260, EG160, EG60, EG36, EG48 service manual GAS CONNECTIONS Cont, Testing The Gas Supply System