Vulcan-Hart EG160, EG260, EG60, EG36, EG48 PILOT LIGHTING AND ADJUSTMENTS Cont, Complete Shutdown

Models: EG48 EG36 EG60 EG260 EG160

1 35
Download 35 pages 54.75 Kb
Page 15
Image 15
Nightly Shutdown: Turn oven burner valve “OFF”.

PILOT LIGHTING AND ADJUSTMENTS (Cont.)

2.Light pilot by depressing the reset button located behind the kick panel (Fig. 12). Light pilot and continue to hold reset button in for 1 minute. If pilot fails to light, turn main gas supply “OFF” and wait 5 minutes before repeating Step 2.

3.After pilot is lit, turn the temperature dial to the desired setting.

Nightly Shutdown: Turn oven burner valve “OFF”.

Complete Shutdown

1.Turn oven burner valve “OFF”.

2.Turn main gas supply “OFF”.

Fig. 12

– 16 –