GAS RESTAURANT RANGE
EG24, 36, 48, 60, 160 AND
EG24 ML-52486 EG36 ML-52487 EG48 ML-114956
EG60 ML-52488 EG160 ML-52489 EG260 ML-52490
FOR YOUR SAFETY
IMPORTANT FOR YOUR SAFETY
EG60
GAS RESTAURANT RANGE MODELS
EG260
EG160
INDEX
GAS RESTAURANT RANGES
PLEASE KEEP THIS MANUAL FOR FUTURE REFERENCE
DESCRIPTION
SERVICE NOTATIONS
DEDICATED TECHNICAL SERVICE HOT LINE
UNITS MOUNTED ON CASTERS
SERVICING SIMPLE CHECKS AND ADJUSTMENTS
ADJUSTMENTS 1.Legs/Casters
CHECKS
2.Oven Door Turnbuckle
SERVICING SIMPLE CHECKS AND ADJUSTMENTS Cont
2A. 24L Oven Door J-BoltAssembly
Oven Pilot Control Button Pilot Adjustment Cap
SERVICING SIMPLE CHECKS AND ADJUSTMENTS Cont
IN OUT
3.Pilot Flame Height
4.Air Shutter Adjustment
SERVICING SIMPLE CHECKS AND ADJUSTMENTS Cont
GAS CONNECTIONS
TESTING THE GAS SUPPLY SYSTEM
GAS CONNECTIONS Cont
HOT TOP AND GRIDDLE TOP PILOT BURNER ADJUSTMENTS
PILOT LIGHTING AND ADJUSTMENTS
HOT TOP AND GRIDDLE TOP BURNERS
Complete Shutdown
OPEN TOP BURNER ADJUSTMENTS
PILOT LIGHTING AND ADJUSTMENTS Cont
OPEN TOP BURNERS
Complete Shutdown
BROILER/GRIDDLE ADJUSTMENTS
PILOT LIGHTING AND ADJUSTMENTS Cont
BROILER/GRIDDLE
Complete Shutdown
Nightly Shutdown Turn oven burner valve “OFF”
PILOT LIGHTING AND ADJUSTMENTS Cont
Complete Shutdown
1.Turn oven burner valve “OFF”
OVEN BURNER ADJUSTMENTS
PILOT LIGHTING AND ADJUSTMENTS Cont
STANDARD OVEN
THERMOSTAT ADJUSTMENTS
Bypass Adjustment
Temperature Calibration
THERMOSTAT ADJUSTMENTS Cont
THERMOSTAT ADJUSTMENTS Cont
THERMOSTAT ADJUSTMENTS Cont
REGULATOR CHECK
REGULATOR CHECK, ADJUSTMENT, INSTALLATION
REGULATOR ADJUSTMENT
REGULATOR CHECK, ADJUSTMENT, INSTALLATION Cont
REGULATOR INSTALLATION
REGULATOR CHECK, ADJUSTMENT, INSTALLATION Cont
STANDARD OVEN AND GRIDDLE THERMOSTAT REPLACEMENT
STANDARD OVEN & GRIDDLE THERMOSTAT REPLACEMENT
STANDARD OVEN & GRIDDLE
THERMOSTAT REPLACEMENT Cont
STANDARD OVEN & GRIDDLE
THERMOSTAT REPLACEMENT Cont
OVEN PILOT CHECK
OVEN PILOT CHECK, REPLACEMENT
OVEN PILOT REPLACEMENT
STANDARD OVEN PILOT SAFETY VALVE CHECK
SAFETY VALVE REPLACEMENT PROCEDURES
6.Install new valve by reversing Steps 1 through
5.Remove safety valve from unit
THERMOCOUPLE CHECK
THERMOCOUPLE CHECK, REPLACEMENT
THERMOCOUPLE REPLACEMENT
OVEN BURNER NOZZLE AND ORIFICE CHECK
OVEN BURNER NOZZLE AND ORIFICE CHECK, REPLACEMENT
OVEN BURNER NOZZLE AND ORIFICE REPLACEMENT
OVEN BURNER CHECK
OVEN BURNER CHECK, REPLACEMENT
OVEN BURNER REPLACEMENT
PILOT ADJUSTMENT VALVE REPLACEMENT
TOP SECTION PILOT CHECK, REPLACEMENT
TOP SECTION PILOT REPLACEMENT
TOP SECTION PILOT CHECK
TOP SECTION BURNER VALVE CHECK
TOP SECTION BURNER VALVE AND NOZZLE REPLACEMENT