Vulcan-Hart EG48, EG160, EG260, EG60, EG36 service manual Safety Valve Replacement Procedures

Models: EG48 EG36 EG60 EG260 EG160

1 35
Download 35 pages 54.75 Kb
Page 29
Image 29
SAFETY VALVE REPLACEMENT PROCEDURES

STANDARD OVEN PILOT SAFETY VALVE CHECK, REPLACEMENT (Cont.)

Fig. 37

5.If the millivolt reading is below 5 MV, replace the thermocouple.

6.If the MV reading is within tolerance, the safety valve should be replaced.

SAFETY VALVE REPLACEMENT PROCEDURES

TOOLS REQUIRED: 716" open end wrench, 1116" open wrench, and 38" open end wrench.

1.Disconnect unit from main gas supply.

2.Disconnect thermocouple from safety valve (Fig. 38).

Fig. 38

– 30 –

Page 29