Vulcan-Hart EG36, EG160 PILOT LIGHTING AND ADJUSTMENTS Cont, Open Top Burners, Complete Shutdown

Models: EG48 EG36 EG60 EG260 EG160

1 35
Download 35 pages 54.75 Kb
Page 13
Image 13
PILOT LIGHTING AND ADJUSTMENTS (Cont.)

PILOT LIGHTING AND ADJUSTMENTS (Cont.)

OPEN TOP BURNERS

1.Turn main gas supply “ON”.

2.Wait 30 seconds and, using a taper, light the open top pilot (Fig. 10).

Fig. 10

3.If pilot fails to light, turn main gas supply “OFF”. Wait 5 minutes and repeat the above procedures.

4.Turn one open top burner valve “ON” to remove air from the gas line. Turn burner “OFF” when gas begins to flow.

OPEN TOP BURNER ADJUSTMENTS

TOOLS REQUIRED: Standard flat blade screwdriver.

1.After pilot is lit, turn open top burners “ON”.

2.Adjust the burner flame, if necessary, by rotating the adjustment screw of the pilot valve located on the manifold pipe (see Fig. 3). Rotate the screw clockwise to decrease and counterclockwise to increase the flame.

Nightly Shutdown: Turn burner valve “OFF”; pilot will remain lit.

Complete Shutdown

1.Turn burner valve “OFF”; pilot will remain lit.

2.Turn main gas supply “OFF”.

– 14 –

Page 13
Image 13
Vulcan-Hart EG36 PILOT LIGHTING AND ADJUSTMENTS Cont, Open Top Burners, Open Top Burner Adjustments, Complete Shutdown