STANDARD OVEN PILOT SAFETY VALVE CHECK, REPLACEMENT (Cont.)

STANDARD OVEN PILOT SAFETY VALVE CHECK, REPLACEMENT (Cont.)

Fig. 37

5.If the millivolt reading is below 5 MV, replace the thermocouple.

6.If the MV reading is within tolerance, the safety valve should be replaced.

SAFETY VALVE REPLACEMENT PROCEDURES

TOOLS REQUIRED: 7/16" open end wrench, 11/16" open wrench, and 3/8" open end wrench.

1.Disconnect unit from main gas supply.

2.Disconnect thermocouple from safety valve (Fig. 38).

Fig. 38