STANDARD OVEN & GRIDDLE THERMOSTAT REPLACEMENT

STANDARD OVEN & GRIDDLE THERMOSTAT REPLACEMENT

STANDARD OVEN AND GRIDDLE THERMOSTAT CHECKS AND CALIBRATION

Refer to THERMOSTAT ADJUSTMENTS on Page 18 of this manual for the procedures for checking and calibrating the thermostat for the standard oven and griddle.

STANDARD OVEN AND GRIDDLE THERMOSTAT REPLACEMENT

TOOLS REQUIRED: Pipe wrench, 6" adjustable wrench, 1/8" flat blade screwdriver, 5/16" socket, and socket wrench.

1.Disconnect unit gas supply and allow unit to cool.

2.From inside the oven cavity, remove the capillary bulb from the clips mounted to the cavity back wall (Fig. 28).

Fig. 28

Fig. 29

3. Remove the top grates or griddle sections required to access the thermostat and capillary wiring (Fig. 29).

— 26 —

Page 26
Image 26
Vulcan-Hart ML-114554 Standard Oven & Griddle Thermostat Replacement, Standard Oven And Griddle Thermostat Replacement