Vulcan-Hart ML-52954 REMOVAL OF CONVECTION OVEN SOLENOID Cont, Disconnect solenoid wire leads Fig

Models: ML-114555 ML-114554 ML-114556 ML-114553 ML-114557 ML-52954 ML-52948 ML-114957 ML-52949 ML-52951 ML-52952 ML-52950 ML-52947 ML-52953

1 52
Download 52 pages 49.32 Kb
Page 50
Image 50
3.Disconnect pilot tubing at tee fitting (Fig. 69).

REMOVAL OF CONVECTION OVEN SOLENOID (Cont.)

3.Disconnect pilot tubing at tee fitting (Fig. 69).

Fig. 69

4.Disconnect pilot tubing at safety valve (Fig. 70).

5.Disconnect solenoid wire leads (Fig. 71).

Fig. 71

6. Disengage safety valve assembly from the manifold area (Fig. 72).

Fig. 70

Fig. 72