Vulcan-Hart ML-114553, ML-52953, ML-52947 Top Section Burner Valve And Nozzle Check, Replacement

Models: ML-114555 ML-114554 ML-114556 ML-114553 ML-114557 ML-52954 ML-52948 ML-114957 ML-52949 ML-52951 ML-52952 ML-52950 ML-52947 ML-52953

1 52
Download 52 pages 49.32 Kb
Page 38
Image 38
TOP SECTION BURNER VALVE AND NOZZLE CHECK, REPLACEMENT

TOP SECTION BURNER VALVE AND NOZZLE CHECK, REPLACEMENT

TOP SECTION BURNER VALVE CHECK

After a long period of use on the range, the top section burner valve can show signs of wear. Check valve for gas leakage and sloppy valve control. Check also for valve nozzle blockage or damage.

TOP SECTION BURNER VALVE AND NOZZLE REPLACEMENT

TOOLS REQUIRED: 1/2" open end wrench, 6" adjustable wrench or standard pipe wrench, 1/4" socket and socket driver.

1.Disconnect main unit gas supply.

2.Remove control panel cover and top grates or griddle section.

3.Remove and check valve and valve nozzle for obstructions and damage.

4.Remove obstruction, or if necessary, replace nozzle or entire valve. When reinstalling, or if the installation of a new valve is required, be sure to use pipe thread sealant on the threaded end which engages the manifold pipe.

CONVECTION OVEN MOTOR AND DOOR SWITCH CHECK, REPLACEMENT

QUICK MOTOR AND DOOR SWITCH CHECK

Turn power switch “ON”. With oven door closed, motor should operate. Open oven door and motor will click off. Motor fan wheel will slow down, turning in a clockwise direction.

MOTOR AND DOOR SWITCH OPERATION CHECK

TOOLS REQUIRED: Volt meter, 5/16" socket, socket driver, short-handle flat blade screwdriver.

1.Open lower kick panel.

2.Locate door micro switch (Fig. 47).

— 38 —

Page 38
Image 38
Vulcan-Hart ML-114553, ML-52953 Top Section Burner Valve And Nozzle Check, Replacement, Top Section Burner Valve Check