5.Attach the lead wires to the replacement socket.

NOTE: Ensure the case is connected to the green ground wire.

6.Insert the socket into the hole in the oven and push until the socket is held in place by the retaining tabs.

7.Install the light bulb and lens.

8.Check for proper operation.

COOLING FAN

Disconnect the electrical power to the machine and follow lockout / tagout procedures.

1.Remove the right side panel as outlined under Covers and Panels.

2.Disconnect the lead wires to the fan motor by removing the wire nuts.

3.Remove the screws securing the air deflector to the fan, then loosen the tab screw holding the fan to the component panel. Rotate the tab so that the fan will clear. Remove the fan.

4.Reverse the procedure to install the replacement fan and check for proper operation.

Fan Installation Tips

The fan must be installed so air is pulled from the rear of the oven and blown into the control area. The arrow on the fan body indicates airflow direction and should be pointing toward the controls.

Ensure the fan is seated squarely against the air tube and the oven bottom.

The air deflector should be angled upward at approximately 30 degrees to properly direct the airflow.

– 19 –

Page 19
Image 19
Vulcan-Hart SG4D service manual Cooling FAN, Fan Installation Tips