HIGH LIMIT THERMOSTAT

Disconnect the electrical power to the machine and follow lockout / tagout procedures.

1.Remove the top four racks from the oven.

2.Remove the high limit thermostat cover/ mounting plate. It is located at the top of the oven cavity.

3.Disconnect the lead wires from the high limit thermostat. Remove the high limit thermostat from the cover mounting plate.

INTERIOR LIGHTS

Disconnect the electrical power to the machine and follow lockout / tagout procedures.

1.Remove the racks from the oven.

2.Unscrew the glass lens for the light being replaced, then unscrew the bulb.

LENS

LENS

OVEN CAVITY

PL-56054

3.Replace bulb, then reverse the procedure to install.

Lamp Assembly

1.Remove the lens and bulb.

2.Remove the springs from the retaining tabs (two places) on the socket.

RETAINING TABS

 

SPRING

 

CROSS SECTIONAL VIEW

PL-56055

4.

Remove the old RTV silicone from the cover

3.

Depress the retaining tabs and pull the socket

 

out from the oven, far enough to disconnect

 

and mating surfaces inside the oven cavity,

 

 

 

the lead wires.

 

and apply new RTV silicone before installing.

 

 

 

 

 

5.

Reverse procedure to install.

4.

Remove the socket from the oven.

 

 

 

 

 

 

 

 

 

 

– 18 –

 

 

Page 18
Image 18
Vulcan-Hart SG4D service manual High Limit Thermostat, Interior Lights, Lamp Assembly