Vulcan-Hart SG4D service manual Troubleshooting, Symptoms Possible Causes

Models: SG4D

1 44
Download 44 pages 15.7 Kb
Page 42
Image 42

TROUBLESHOOTING

SYMPTOMS

POSSIBLE CAUSES

 

 

 

Line voltage.

Blower motor doesn't run in OVEN COOL or

Power/Master switch malfunction.

ON position.

Fan switch malfunction.

 

Interconnection wiring malfunction.

 

 

Blower motor doesn't run in the ON position.

Door switch malfunction.

Power/Master switch contacts inoperative.

Cool Down functions OK.

Interconnecting wiring malfunction.

 

 

 

Blower motor doesn't run in OVEN COOL

Power/Master switch malfunction.

position. Runs OK in ON position.

Interconnection wiring malfunction.

 

 

 

Shorted electrode on igniter/flame sense.

 

Igniter cable (high voltage) OPEN.

Gas does not ignite.

Heat relay malfunction.

Centrifugal switch in blower motor inoperative.

No spark.

Transformer inoperative.

No Ignition light is not ON.

High limit thermostat open.

 

 

Interconnecting wiring malfunction.

 

Ignition module malfunction.

 

 

 

Gas solenoid valve off or inoperative.

 

Manual gas valve closed.

Sparks but gas does not ignite.

Gas supply OFF or insufficient gas pressure.

 

Inerconnecting wiring malfunction.

 

Igniton module malfunction.

 

 

 

Igniter lead connections malfunction.

 

Igniter ground inoperative.

Gas ignites but will not maintain flame.

Igniter/flame sense malfunction or maladjusted.

Insufficient gas pressure.

 

 

Snorkel vent plugged, obstructed or missing.

 

Incorrect polarity from transformer to ignition module.

 

 

 

Temperature probe malfunction.

 

Temperature control board malfunction.

Excessive or low heat.

Gas pressure insufficient.

 

Gas orifice plugged or obstructed.

 

Power level may be set to low.

 

 

– 42 –

Page 42
Image 42