TESTING THE GAS SUPPLY SYSTEM
When the gas supply pressure exceeds 1/2 psig (3.45 kPa), the steamer and its individual shutoff valve must be disconnected from the gas supply piping system.
When the gas supply pressure is 1/2 psig (3.45 kPa) or less, the steamer should be isolated from the gas supply system by closing its individual manual shutoff valve.
FLUE GAS EXHAUST
DO NOT obstruct the flow of flue gases from the flue located on the rear of the steamer.
It is recommended that the flue gases be vented to the outside of the building through a ventilation system installed by qualified personnel.
Information on the construction and installation of ventilating hoods may be obtained from Vapor Removal from Cooking Equipment,
ELECTRICAL CONNECTION — GAS STEAMERS & STEAM GENERATORS
WARNING: APPLIANCES EQUIPPED WITH A FLEXIBLE ELECTRIC SUPPLY CORD ARE PROVIDED WITH A
WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL ELECTRICAL CODES.
WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW LOCKOUT / TAGOUT PROCEDURES.
ELECTRICAL DATA
|
|
|
| Minimum Circuit Ampacity |
Volts | Hertz | Phase | Machine Amps | Maximum Protective Device |
|
|
|
| AMPS |
120 | 60 | 1 | 3.0 | 15 |
Compiled in accordance with the National Electrical Code,
The cord and plug supplied, is a suitable durable cord with molded plug and is provided with a proper strain relief.
If a
The wiring diagram is located on the door of the boiler.
Connect the steamer to the electrical supply after the gas connections have been made.