VHX SERIES STEAMER - TROUBLESHOOTING
COOKING COMPARTMENT CONTROLS
SYMPTOM |
| POSSIBLE CAUSES |
|
|
|
Cooking compartments do not operate. | 1. | No power to cooking compartment controls. |
| 2. | Pressure in boiler is below compartment pressure switch |
|
| setting. |
| 3. | Manual intake shutoff valve in the off position. |
| 4. | Door switch malfunction. |
| 5. | Timer malfunction. |
| 6. | Malfunctioning pressure switch in compartment. |
| 7. | Interconnecting wiring malfunction. |
|
|
|
Steam generated inside compartment | 1. | Steam supply solenoid not fully closing (clogged or dirty). |
when timer is off. | 2. | Timer contacts 1 & 3 closed. |
|
|
|
Timer motor does not run. | 1. | Door open or door switch malfunction. |
| 2. | Timer not receiving power or malfunction. |
|
|
|
Door not closing properly. | 1. | Door latch assembly malfunction or out of adjustment. |
| 2. | Striker adjustment. |
|
|
|
Door won’t open. | 1. | Latch won’t release. |
|
|
|
Buzzer not operating. | 1. | Timer malfunction. |
| 2. | Buzzer malfunction. |
|
|
|
Compartment leaks water around door or | 1. | Compartment drain screen clogged. |
water accumulating in compartment . | 2. | Door out of adjustment. |
| 3. | Drain line obstructed or not to an open air gap drain. |
| 4. | Worn or damaged door gasket. |
| 5. | Steamer not level. |
|
|
|
Steam leaks around door. | 1. | Door out of adjustment. |
| 2. | Worn or damaged door gasket. |
| 3. | Drain line obstructed or not to an open drain. |
|
|
|
Page 45 of 48 |