VHX SERIES STEAMER - ELECTRICAL OPERATION

RELAY BOARD

Layout, Legend & Diagnostic Test Points

The relay board provides a centralized location for wire harness connections and power transfer through board relays (K1-K4) to the other steamer controls. Also, provides for condition or component troubleshooting by utilizing seven voltage test points (T1-T7) on the board to verify the voltage status for the condition or component in the operating sequence. When the condition for the component<s voltage measurement is satisfied or activated, 120VAC can be measured between T1 (ref.) and T2 thru T7 test points to indicate whether the condition or component is receiving voltage to energize and operate. If the voltage is not present, then the condition or component has not been energized or is not activated.

Page 31 of 48

 

F25154 (February 2004)

 

Page 31
Image 31
Vulcan-Hart VHX24E service manual Relay Board, Layout, Legend & Diagnostic Test Points