Vulcan-Hart VIR1CF, VIR1BF, VIR1SF, VIR1F Broiler Control Valve, Main Gas Valve, Before First Use

Models: VIR1F VIR1SF VIR1BF VIR1CF

1 32
Download 32 pages 26.14 Kb
Page 12
Image 12
Broiler Control Valve

Broiler Control Valve

Grease Collector Handle

Main Gas Valve

Broiler

Control

Valves

Regulates the flow of gas to the broiler burner. To operate the valve, turn it counterclockwise. Turn the knob clockwise to the OFF position to shut burners down.

The grease pan must be checked frequently and emptied when it is about 3/4 full. To check or empty the grease collector pan, pull the grease collector handle straight out until the pan is partially exposed. If the grease pan is being emptied, carefully remove the grease pan completely from the broiler. Dispose of the grease and return the pan to the broiler before continuing to broil.

When opened, allows gas to flow to the left and right burner and pilots. To open the valve, turn the knob counterclockwise. To close, turn the knob clockwise.

Grease

Collector

Handle

Main

Gas

Valve

BEFORE FIRST USE

Burn off protective grid oils before cooking food products. With grid in full-up position, operate broiler at full output for approximately 1 hour or until smoking stops. The burning will cause a somewhat unpleasant odor; this is normal.

– 12 –

Page 12
Image 12