WATER LEVEL GAUGE
Check the water level gauge sight glass daily. The correct water level is approximately 1" (2.5 cm) of water visible in the water level gauge sight glass. Extremely murky water in the sight glass indicates bad water conditions. The boiler should be blown down. If conditions persist, have the boiler inspected and cleaned by your local
FLUE
Annually, when the steamer is cool, check the flue and clear any obstructions.
SCALE RELATED MAINTENANCE
Periodic maintenance is necessary to keep your boiler clean and efficient. Initially, after three months of steamer usage, it is recommended that you have your
Cathodic protector(s) are provided inside the boiler to reduce boiler and component corrosion and reduce accumulation of scale from forming on the boiler interior walls. The cathodic protector(s) will be consumed. How fast the cathodic protector(s) will be consumed depends upon the chemical makeup of the feed water and the average volume of feed water used. An inspection by service personnel is recommended so that the expected normal life of the cathodic protector(s) can be estimated under your operating conditions. Thereafter, the cathodic protector(s) can be serviced at the appropriate frequency for your situation.
LUBRICATION
The door screw was factory lubricated with
TROUBLESHOOTING
Symptoms | Possible Causes | |
|
| |
Steamer will not heat or build pressure. | 1. Water supply to steamer is not turned on. | |
| 2. | Water filter may be clogged. |
| 3. | Main gas supply valve may be turned off. |
| 4. | Electrical supply may be off or disconnected. |
| 5. | Combination gas valve may be turned off. |
| 6. | Ignition switch may be turned off. |
|
| |
Water accumulates in compartment. | Drain may be clogged. Clear drain. | |
|
| |
Other problems. | Contact Service. | |
|
|
|
SERVICE AND PARTS INFORMATION
To obtain service and parts information concerning this steamer, contact the
FORM 35409 Rev. A (Aug. 2004) | – 16 – | PRINTED IN U.S.A. |
|
|