INSTALLATION DRAWING

INSTALLATION DRAWING

Models VL2GSS & VL3GSS

LEGEND

GAS CONNECTION: 3/4" NPT

BOILER FEED CONNECTION FOR FILTERED WATER: 1/4" NPT

WATER CONNECTION FOR BOILER DRAIN CONDENSER: 1/4" NPT

ELECTRICAL CONNECTION: 120 V, 60 HZ, 1 PH, 300 WATTS MAX

DRAIN: 31/2" DIA.

PROVIDE FLOOR SINK FOR OPEN GAP TYPE DRAIN.

DO NOT PLACE FLOOR SINK DIRECTLY UNDER STEAMER. DO NOT CONNECT SOLIDLY TO ANY DRAIN CONNECTION.

NOTE: DIMENSIONS WHICH LOCATE THE ABOVE CONNECTIONS HAVE A TOLERANCE OF + OR - 3 IN. (75 MM).

NORMAL DIMENSIONS ARE IN INCHES. DIMENSIONS IN ( ) ARE IN MILLIMETERS.

EQUIPMENT CLEARANCES

TO COMBUSTIBLE CONSTRUCTION

REAR: 6 INCH (152 MM) MINIMUM

LEFT SIDE: 6 INCH (152 MM) MINIMUM

RIGHT SIDE: 6 INCH (152 MM) MINIMUM

WATER QUALITY MUST BE WITHIN THESE GUIDELINES:

SUPPLY PRESSURE:

20 - 60 PSIG

HARDNESS*:

LESS THAN 3 GRAINS

SILICA:

LESS THAN 13 PPM

TOTAL CHLORINE:

LESS THAN 4.0 PPM

pH RANGE:

7 – 8

UNDISSOLVED SOLIDS:

LESS THAN 5 MICRONS

* 17.1 PPM = 1 GRAIN OF HARDNESS

Fig. 3

– 8 –