GAS CONNECTION

GAS CONNECTION

CAUTION: All gas supply connections and any pipe joint compound used must be resistant to the action of liquefied petroleum gases.

Codes require that a gas shutoff valve be installed in the gas line ahead of the steamer.

Connect the gas supply line to the gas valve on the steamer. Make sure the pipes are clean and free of obstructions, dirt and piping compound.

The gas line must be capable of delivering gas to the steamer without excessive pressure drop at the rate specified on the nameplate. Recommended gas line pressure is 7" W.C. (17.8 cm W.C.) for natural gas and 11" W.C. (27.9 cm W.C.) for propane gas. Refer to Fig. 3 on page 8. With adequate gas pressure, a 3/4" (1.9 cm) inside diameter black iron pipe to the steamer should be satisfactory. If adequate pressure is not available, a larger line such as 1" (2.5 cm) inside diameter may be used to assure adequate gas delivery.

IMPORTANT: Check burner manifold pressure with a manometer at the 1/8" (0.32 cm) tap on the gas valve to make sure it is 4" W.C. for natural gas or 9" W.C. for propane.

WARNING: PRIOR TO LIGHTING, CHECK ALL JOINTS IN THE GAS SUPPLY LINE FOR LEAKS. USE SOAP AND WATER SOLUTION. DO NOT USE AN OPEN FLAME.

TESTING THE GAS SUPPLY SYSTEM

When test pressures exceed 1/2 psig (3.45 kPa), the steamer and its individual shutoff valve must be disconnected from the gas supply piping system.

When test pressures are 1/2 psig (3.45 kPa) or less, the steamer must be isolated from the gas supply system by closing its individual manual shutoff valve.

FLUE-GAS EXHAUST — A VENTILATING HOOD IS RECOMMENDED

DO NOT obstruct the flow of flue gases from the flue located on the rear of the steamer. It is recommended that the flue gases be ventilated to the outside of the building through a ventilation system installed by qualified personnel.

Information on the construction and installation of ventilating hoods may be obtained from the standard for the Removal of Vapors from Commercial Cooking Equipment, NFPA No. 96 (latest edition), available from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.

ELECTRICAL CONNECTION

WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL ELECTRICAL CODES.

WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW LOCKOUT / TAGOUT PROCEDURES.

The electrical diagram for the compartments is located on the inside of the upper left side panel. The electrical diagram for the steam generator is located on the inside of the left front door.

The electrical supply (120 volt, 60 Hertz, 1 Phase) must be connected to the pigtail leads in the junction box located next to the boiler control box. Use #18 AWG copper wire suitable for at least 105°C temperature. Connect a grounding wire to the ground lug in the junction box.

– 7 –