5.7 How to scan
NOTE: To scan, make sure your scanner is not connected to the computer.
1.Turn on scanner by pressing the [Power/Scan] button for 2 seconds.
2.Hold the document firmly with one hand on a flat surface.
3.Place the scanner on the edge of the paper approximately 5/8 to 3/4 of an inch onto the page to ensure the whole document can be scanned. Make sure to keep the scanning area in between the scanning width indicators marked on the side of the scanner.
4. Hold the scanner flat against the material and then press the [SCAN] button once.
5.Slide the scanner slowly, keeping your hand stable to get the best quality picture.
6.Press the [SCAN] button again to stop scanning.
6. Viewing your scans
1.Connect your scanner to your computer and then turn on your scanner.
2.Your computer should recognize the scanner as a “Removable Disk.”
Click “Open folder to view files” to view and import scans.
Note: If the Removable Device Window did not launch automatically, go to your “My Computer” and find the device under Removable Storage.
7. Specifications
Image sensor | Color Contact Image Sensor | ||
|
|
| |
Number of sensor | 5136 dots(1st~5104 dots available) | ||
|
|
| |
Resolution | Low resolution : 300dpi(default) | ||
High resolution: 600dpi |
| ||
|
| ||
Maximum scanning | Color High resolution |
| 13 Seconds |
Mono High resolution |
| 6.0 Seconds | |
speed for Letter size |
| ||
Color Low resolution |
| 3.0 Seconds | |
document |
| ||
Mono Low resolution |
| 2.0 Seconds | |
|
| ||
|
|
|
|
Capacity (Based on | 600dpi color |
| 220 Photos(Min.) |
1GB microSD card. |
| ||
|
|
| |
600dpi mono |
| 290 Photos(Min.) | |
Scan Letter size file, |
| ||
the quantity of scans |
|
|
|
300dpi color |
| 780 Photos(Min.) | |
vary depending on |
| ||
|
|
| |
300dpi mono |
| 1280 Photos(Min.) | |
the content complexity) |
| ||
Scan width | 8.27" |
|
|
Scan length | 300dpi: 50"(Max), 600dpi: 25"(Max) | ||
File format | JPEG |
| |
LCD | Scanning status display |
| |
Auto Power Off | 3 Minutes |
| |
USB Port | USB 2.0 high speed |
| |
External memory | microSD/microSDHC Card |
| |
Standard Battery | 2XAA alkaline batteries |
|
8. Computer system minimum requirement
| Windows® XP, Windows® Vista™, Windows® 7 |
Operating System | and Mac OS® 10.4 or above |
| (direct |
CPU | Pentium II or above |
|
|
RAM | 64MB |
Interface | USB port |
|
|
9. Troubleshooting
Problem | Cause | Solution |
|
|
|
Cannot turn on the | 1. Low battery power. | Replace or install the |
scanner | 2. Battery not inserted | battery correctly |
| properly |
|
|
|
|
Pictures cannot be | 1. microSD card has not | 1. Install microSD card |
saved when you are | been installed | 2. Download the pictures |
scanning them | 2. Memory is full | from the scanner to the |
| 3. The microSD card has | computer to create |
| not been formatted | storage space |
| properly | 3. Reformat your microSD |
|
| card. Please refer to |
|
| section 5.3 |
|
|
|
Computer does not | Connection failure. | Make sure all cable |
recognize your |
| connections are secured. |
scanner when |
| Restart the computer if |
connected. (You |
| necessary |
cannot find |
|
|
removable disk) |
|
|
|
|
|
The battery life is | Use wrong type of battery | Replace with new |
very short |
| 2x AA alkaline batteries |
|
|
|
Blurry images | The lens of scanner is | Clean the lens with soft |
| dirty | dry cloth |
|
|
|
ERR. LED is on when | Scanning speed is too | Press the Power/Scan |
scanning a document | fast | button to reset your scan. |
|
| Scan the document again. |
|
|
|
10. ABBYY® OCR Software
(Optional, not required to install to operate scanner)
Compatible with Windows® XP, Windows® Vista™, Windows® 7
To access the software User’s Manual go to the Help menu for instructions on how to use the OCR software application:
1.Load and open the ABBYY software.
2.Press the “F1” key located on your keyboard to launch the “Help” menu from the software.
3.OR, locate the ABBYY icon found next to the Time indicator on your computer’s taskbar and then right click on the icon to access the “Help” menu.
FCC (Federal Communications Commission)
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1)This device may not cause harmful interference, and
(2)this device must accept any interference received, including interference thay may cause undesired operation.
Windows® XP, Windows® Vista™, Windows® 7 are registered trademarks of Microsoft Corporation. Mac OS® 10.4 is a registered trademark of Apple Inc.
ABBYY® is a registered trademark of ABBYY Software Ltd. microSD and microSDHC logo is a trademark of