WARNING

If a metal container is used, it is necessary to ground the spray gun and container. To do this, hold a metal portion of the gun against the edge of the metal container. Failure to do so may lead to static electric discharge, which may cause a fire.

3.Turn the pressure control knob counterclockwise to the lowest setting.

Pressure Control

Knob

4. Set the PRIME/SPRAY valve to the PRIME.

PRIME/SPRAY Valve

PRIMESPRAY

5.Turn the ON/OFF switch to ON.

6.Turn the pressure control knob clockwise slowly until fluid starts coming through the return tube. Use the least amount of pressure necessary to keep the fluid flowing. When all of the test fluid has been cleaned out of the system, soapy water will flow through the return tube.

7.Turn the pressure control knob to its lowest setting and replace the container of soapy water with a container of clear water.

8.Turn the pressure control knob clockwise slowly until water running through the return tube is clear.

9.Turn the pressure control knob counterclockwise to the lowest setting. Replace the container of clean water with a container of latex paint.

10.Turn the pressure control knob clockwise slowly until paint comes through the return tube.

11.Place the return tube into the operating position above the paint container. Keep recirculating paint through the system until the paint coming through the return tube is free of air bubbles.

12.Turn the pressure control knob counterclockwise to the lowest setting. The unit is now ready to use.

CAUTION

Keep the spray gun locked and in the OFF position during these steps.

Purging the system for solvent-based paint

1.Place a container of paint under the paint suction tube. Have a waste container ready to catch the purged fluid.

2.Detach the return tube from the fluid section and secure it in the waste container so that it will not come out.

Return Tube

WARNING

If a metal container is used, it is necessary to ground the spray gun and container. To do this, hold a metal portion of the gun against the edge of the metal container. Failure to do so may lead to static electric discharge, which may cause a fire.

3.Turn the pressure control knob counterclockwise to the lowest setting.

Pressure Control

Knob

4. Set the PRIME/SPRAY valve to the PRIME.

PRIME/SPRAY Valve

PRIMESPRAY

5.Turn the ON-OFF switch to ON.

6.Turn the pressure control knob clockwise slowly until fluid starts coming through the return tube. Use the least amount of pressure necessary to keep the fluid flowing. When all of the test fluid has been cleaned out of the system, paint will flow through the return tube.

7.Turn the pressure control knob to its lowest setting.

8.Place the return tube into the operating position above the paint container. Keep recirculating paint through the system until the paint coming through the return tube is free of air bubbles.

9.The unit is now ready to use.

© SprayTECH Corporation. All rights reserved.

5

English