TROUBLE SHOOTING SECTION
SYMPTOM | PROBABLE CAUSE | CORRECTIVE ACTION |
Opener won’t work from wall button or | No power to opener. | Check cord to outlet, wall switch and |
radio control. |
| circuit breaker. |
| Short circuit in wires to opener or wall | Isolate by disconnecting the wires at |
| button. | the opener from the wall station. |
| Motor Protector trips open due to ex- | Allow motor to cool for 20 minutes and |
| cessive use. | try again. |
Opener works from wall button but not | Radio control system | Weak or dead battery in transmitter- |
from radio control. |
| replace. |
|
| Security Code not matched between |
|
| receiver and transmitter (see page 16) |
|
| If two or more transmitters don’t work, |
|
| have Motor Control Board Tested. |
Door does not open and opener light | Something obstructing door travel. | Disconnect door from operator. Oper- |
flashes. |
| ate door by hand to locate obstruction |
|
| or call a service person. |
| Insufficient opening force. | Adjust opening force. (See Adj. #1). |
| Build up of ice and snow around door. | Shovel and clear door area. |
Door does not open fully and light | Open Limit not set properly. | Adjust Open Travel with screwdriver, |
does not flash. |
| turn |
|
| ting. 1/4 turn equals to 1” of travel (see |
|
| Step 28). |
Door stops and does not close fully. | Close Limit not set properly. | Adjust Close Travel with screwdriver, |
|
| turn clockwise to desired setting. 1/4 |
|
| turn equals 1” of travel (See Step 27). |
Door closes and then returns to fully | Door arm adjustment. | Adjust rod in tube to provide 1” of |
open position and opener light flashes. |
| “cushion” compression when door is |
|
| fully closed (See Step 24 and 26). |
| Close travel adjustment is set beyond | Adjust Close Travel with screwdriver, |
| normal door position. | turn clockwise to desired setting. 1/4 |
|
| turn equals 1” of travel (See Step 27). |
| Obstructions on floor. | Check for stones or ice under door |
|
| and remove. |
When activated with door in fully open | Infrared Safety Sensors out of adjust- | Infrared Safety Sensors alignment |
position, door travels for 1 second, | ment or defective. | should be checked per instructions. |
stops, and returns to fully open posi- |
| (See Step 21 and 22). |
tion and light begins to flash. | Batteries in Wireless Safety Sensors. | Check batteries and contact points. |
| ||
| Obstructions in door opening. | Check for object blocking Infrared |
|
| Safety Sensors. |
Door reverses travel before reaching | Activation of obstruction sensing sys- | Check for binding in door travel (door |
fully closed position and opener light | tem. | “stops”, door tracks, etc). |
flashes. | Loose or hanging objects on door acti- | Remove objects. |
| ||
| vating Infrared Safety Sensor |
|
| Insufficient closing force. | Adjust closing force. (See Adj. #1). |
Door stops travel for 1 second at mid- | Weak battery in Wireless Infrared | Replace batteries in Wireless Infrared |
point during close and then continues | Safety Sensors. | Safety Sensors. |
to close. |
|
|
Door fully opens and then light flashes. | Open limit is set too high and trolley is | Adjust Open Travel with screwdriver, |
| hitting the stop bolt. | turn |
|
| ting. 1/4 turn equals to 1” of travel (see |
|
| Step 28). |