Weber 1500 owner manual Install igniter, Purge air from gas lines

Models: 1500

1 36
Download 36 pages 61.01 Kb
Page 19
Image 19

Step 11

Install igniter

Note - The igniter wires are already attached to the Gas Catcher Ignition Chamber and the igniter. This was done to factory test the ignition system.

The igniter lock nut is on the igniter.

Insert the top of the igniter up through the large part of the keyhole in the frame brace. Figure 19 (b). Loosen the igniter lock nut and slide the igniter into the small part of the keyhole. Figure 19 (c). Tighten the igniter lock nut. Figure 19.

Note - If the igniter works loose, carefully tighten the igniter lock nut with an adjustable wrench or pliers.

(a)

Frame brace

(b)

Figure 19

 

 

 

Keyhole in

 

(c)

frame brace

Igniter lock nut

 

 

 

Frame brace

Small part of keyhole in frame brace

Step 12

Purge air from gas lines

You will need: one burner control knob.

mDANGER

Be sure there are no sparks or open flames in the area while purging. This can cause fire, explosion or serious bodily injury.

It is necessary to bleed the air out of newly installed gas lines. Turn gas supply ON at the source. Put on the front burner control knob. Push the front burner control knob down and turn to HI. When you start to smell gas, turn front burner control knob to OFF. Figure 20.

Figure 20

19

Page 19
Image 19
Weber 1500 owner manual Install igniter, Purge air from gas lines