d)Unlatch the Spider Stopper Guards and remove. Figure 9.

i)To reinstall the burners, reverse steps c) through g).

mCAUTION: The burner openings must be positioned properly over the valve orifices. Figure 13 (a).

Check proper assembly before fastening manifold in place. Figure 13 (b).

Figure 9

e)Disconnect gas supply line.

f)Remove the manifold bracket and unscrew the two wing nuts that hold the manifold to the cooking box. Pull the manifold and valve assembly out of the burners and carefully set it down. Figure 10.

View from behind cooking box

Wing nuts

(a)

Burner valve

Valve orifice

(b)

Figure 13

Figure 10

g)Slide the burner assembly out from under the guide screw and washer in the corners of the cooking box. Figure 11.

Guide screw

Figure 11

h)Lift and twist the burner assembly slightly, to separate the crossover tube from the burners. Figure 12. Remove the burners from the cooking box.

Crossover tube

Figure 12

j)Reinstall the Spider Stopper Guards. Slightly rotate the Spider Stopper Guards so that the seams are in line with the Venturi fins. There should be no gaps in the seams or in the fit around the burners and valves. Figure 14.

Check fit around valve

Venturi fin

Check fit around burner

Figure 14

mCAUTION: If the Spider Stopper Guards do not fit tightly, contact Weber-Stephen Customer Service.

k) Reconnect gas supply line. See “Check for gas leaks”.

31

Page 31
Image 31
Weber 1500 owner manual Reconnect gas supply line. See Check for gas leaks