Install Gas Supply

 

 

 

 

Gas Line Piping

General Specifications for Piping

 

 

■ If the length of the line required does not exceed 50

 

Note - Contact your local municipality for building

 

 

feet, use a 5/8" O.D. tube. One size larger should be

 

 

 

 

 

 

 

 

codes regulating outdoor gas barbecue

 

 

used for lengths greater than 50 feet.

 

 

 

 

 

 

 

 

installations. In absence of Local Codes, you must

 

 

■ Gas piping may be copper tubing, type K or L;

 

 

 

 

 

 

 

confirm to the latest edition of ANSI Z223.1. WE

 

 

polyethylene plastic tube, with a minimum wall

 

 

 

 

 

 

 

 

 

 

RECOMMEND THAT THIS INSTALLATION BE DONE

 

 

thickness of .062 inch; or standard weight (schedule

 

 

 

 

 

 

 

 

BY A PROFESSIONAL.

 

 

 

 

40) steel or wrought iron pipe.

 

 

 

 

 

 

 

 

 

 

Some of the following are general requirements taken

 

 

■ Copper tubing must be tin-lined if the gas contains

 

 

 

 

 

 

 

 

 

from ANISI Z223.1 latest edition for complete

 

 

more than 0.3 grams of hydrogen sulfide per 100 cubic

 

 

 

 

 

 

 

 

 

specifications.

 

 

 

 

feet of gas.

■ This barbecue is designed to operate at 7 inches of

 

 

■ Plastic tubing is suitable only for outdoor,

water column pressure (.2526 psi).

 

 

underground use.

 

 

 

 

 

 

 

 

 

■ A manual shut-off valve must be installed outdoors,

 

 

■ Gas piping in contact with earth, or any other

immediately ahead of the quick disconnect.

 

 

material which may corrode the piping, must be

 

■ An additional manual shut-off valve indoors should

 

 

protected against corrosion in an approved manner.

 

be installed in the branch fuel line in an accessible

 

 

■ Underground piping must have a minimum of 18"

 

location near the supply line

 

 

 

 

cover

 

 

 

 

 

 

■ The quick disconnect connects to a 3/8 inch NPT

 

 

Test Connections

 

 

 

 

thread from the gas source. The quick disconnect

 

 

 

fitting is a hand-operated device that automatically

 

 

All connections and joints must be thoroughly tested

 

shuts OFF the flow of gas from the source when the

 

 

for leaks in accordance with local codes and all listed

 

barbecue is disconnected

 

 

 

 

procedures in the latest edition of ANSI Z223.1

 

 

 

■ The quick disconnect fitting can be installed

 

 

 

 

horizontally, or pointing downward. Installing the fitting

 

 

m DANGER

 

 

with the open end pointing upward can result in

 

 

Do not use an open flame to check for gas

 

 

collecting water and debris.

 

 

 

 

 

 

 

leaks. Be sure there are no sparks or open

 

■ The dust covers (supplied plastic plugs) help keep

 

 

 

 

 

flames in the area while you check for gas

 

the open ends of the quick disconnect fitting clean

 

 

 

 

while disconnected.

 

 

 

 

leaks. This will result in a fire or explosion

 

 

 

 

 

 

 

■ Pipe compound should be used which is resistant to

 

 

which can cause serious bodily injury or

 

 

 

the action of natural gas when connections are made.

 

 

death and damage to property.

 

 

 

■ The outdoor connector must be firmly attached to

 

 

 

 

 

 

 

 

rigid, permanent construction.

 

 

 

 

 

 

 

 

 

 

 

 

m WARNING: Do not route the 12 foot hose under

 

 

 

 

 

 

 

 

a deck. The hose must be visible.

 

 

 

 

 

Inside wall

Gas supply

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outside wall

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Shut off

 

 

 

 

 

 

 

 

 

 

 

 

Quick Disconnect

Locking shut off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B-6

Page 16
Image 16
Weber 55204 manual Do not use an open flame to check for gas, Leaks. Be sure there are no sparks or open