Connect side burner to manifold | Install Gas Supply |
| |
m WARNING: Make sure gas supply is off. | General Specifications for Piping | ||
Connect the side burner hose as follows: | Note - Contact your local municipality for building | ||
1) Slide back the collar of the quick disconnect on the | codes regulating outdoor gas barbecue installa- | ||
manifold. | tions. In absence of Local Codes, you must con- | ||
2) Push the male fitting of the side burner hose into | firm to the latest edition of ANSI Z223.1. WE REC- | ||
the quick disconnect, and maintain pressure. Slide | OMMEND THAT THIS INSTALLATION BE DONE BY | ||
the collar closed. | A PROFESSIONAL. |
| |
Quick disconnect will be engaged. | Some of the following are general requirements taken | ||
Check to be sure the side burner valve is OFF. Push | from ANISI Z223.1 latest edition for complete specifi- | ||
the side burner control knob down and turn it clock- | cations. |
| |
wise. If it doesn’t turn, the valve is OFF. If it does turn, | ■ This barbecue is designed to operate at 7 inches of | ||
continue turning it clockwise until it stops, then the | water column pressure (.2526 psi). | ||
burner valve is OFF. | ■ A manual | ||
| immediately ahead of the quick disconnect. | ||
(1) | ■ An additional manual | ||
be installed in the branch fuel line in an accessible | |||
| |||
| location near the supply line |
| |
| ■ The quick disconnect connects to a 3/8 inch NPT | ||
| thread from the gas source. The quick disconnect | ||
| fitting is a | ||
| shuts OFF the flow of gas from the source when the | ||
| barbecue is disconnected |
| |
| ■ The quick disconnect fitting can be installed horizon- | ||
(2) | tally, or pointing downward. Installing the fitting with the | ||
open end pointing upward can result in collecting | |||
| water and debris. |
| |
| ■ The dust covers (supplied plastic plugs) help keep | ||
| the open ends of the quick disconnect fitting clean | ||
| while disconnected. |
| |
| ■ Pipe compound should be used which is resistant to | ||
| the action of natural gas when connections are made. | ||
| ■ The outdoor connector must be firmly attached to | ||
| rigid, permanent construction. |
| |
| m WARNING: Do not route the 12 foot hose under | ||
| a deck. The hose must be visible. | ||
|
| Gas supply | |
| Inside wall |
| |
| Outside wall |
| |
|
| Shut off | |
| Quick Disconnect | Locking shut off | |
|
|