Make sure all parts are properly tightened each time the weight system is used. Replace any worn parts immedi- ately. The weight system can be cleaned using a damp cloth and mild non-abrasive detergent. Do not use solvents.

TIGHTENING THE CABLES

Woven cable, the type of cable used on the weight system, can stretch slightly when it is first used. If there is slack in the cables before resistance is felt, the cables should be tightened. To tighten the cables, first insert the weight pins into the centers of the weight stacks. Slack can be removed from the cables in several ways:

See drawing 1. To tighten the Squat Cable (73) or the Swivel High Cable (not shown), first loosen the 1/2” Nut (118) on the end of the Cable, away from the 1/2” Washer (1). Screw the end of the Cable farther into the Weight Tube (43). Then, retighten the Nut against the Washer.

See drawing 2. To further tighten the Squat Cable (73), first remove the 3/8” Nylon Locknut (87), the 3/8" x 2" Bolt (100), Cable Trap (68), and 3 1/2” Pulley (78) from the indicated bracket on the Long Base (120). Reattach the Pulley and Cable Trap between a lower set of holes with the Bolt and Nylon Locknut.

See drawing 3. To tighten the other five cables, first remove the upper or lower 3/8” Nylon Locknut (87), 3/8” x 2” Bolt (100), 3 1/2” Pulley (78), and Cable Trap (68) from the Pulley Plates (63) or Small Pulley Plates (not shown). Reattach the Pulley and the Cable Trap between a set of holes closer to the center of the Pulley Plates with the Bolt and Locknut.

See drawing 4. To remove additional slack, first remove the 3/8” Nylon Locknut (87), 3/8” x 2” Bolt (100), 3 1/2” Pulley (78), and Cable Trap (68) from the “U”-bracket (64). Reattach the Pulley and the Cable Trap between the higher set of holes in the “U”-bracket with the Bolt and Nylon Locknut.

Do not overtighten the cables. If the cables are overtight- ened, the top weights will be lifted off the weight stacks.

If a cable slips off the pulleys repeatedly, it may have become twisted. Remove the cable and re-install it. If the cables need to be replaced, see ORDERING REPLACE- MENT PARTS on the back cover of this manual.

1

 

 

73

 

118

 

1

43

 

2

68

73

 

 

87

 

78

 

120

100

 

3

 

 

63

100

 

68

87

 

78

 

4

 

100

 

68

64

 

78

87

25