FEATURES & OPERATING CONTROLS (continued)
ITEM | DESCRIPTION | COMMENT |
VENTILATOR SECTION CONTROLS | ||
V1 | POWER SWITCH | Energizes blower motor. If, after 10 seconds, proper |
|
| conditions are met, cooktop is energized. |
V2 | POWER ON INDICATOR | GREEN. Glows when POWER switch is ON. |
V3 | CHECK FILTERS ALARM | AMBER. Glows if one or more filters are out of position. Check |
| INDICATOR | all filters and baffles for proper installation. |
V4* | REPLACE PREFILTER | AMBER. Glows when PREFILTER is approaching the end of its |
| ALARM INDICATOR | service life and must soon be replaced. |
V5* | REPLACE FILTER PACK | AMBER. Glows when FILTER PACK is approaching the end of |
| ALARM INDICATOR | its service life and must soon be replaced. |
V6* | SERVICE REQUIRED | RED. Glows when PREFILTER and/or FILTER PACK has |
| ALARM INDICATOR | reached the end of its service life and is too loaded to allow |
|
| sufficient air flow. Filter MUST be replaced. Appliance is SHUT |
|
| DOWN until expended filters are replaced. |
*See PRECAUTIONS & GENERAL INFORMATION, pages 6 & 7 for special procedures regarding prefilters and filter packs.
COOKTOP SECTION CONTROLS
H1 | LEFT FRONT HOTPLATE | Infinite switch control of temperature of one hotplate section. |
| CONTROL |
|
H2 | LEFT REAR HOTPLATE | Infinite switch control of temperature of one hotplate section. |
| CONTROL |
|
H3 | RIGHT REAR HOTPLATE | Infinite switch control of temperature of one hotplate section. |
| CONTROL |
|
H4 | RIGHT FRONT HOTPLATE | Infinite switch control of temperature of one hotplate section. |
| CONTROL |
|
H5 POWER ON INDICATOR
H6 HOT SURFACE INDICATOR
AMBER. Glows when associated temperature control is turned ON.
RED. Glows any time surface is above 150ºF
OPTIONAL WARMER SECTION CONTROLS
W1 | WARMER TEMPERATURE | Infinite switch control of temperature of one warmer drawer. |
| CONTROL |
|
W2 | POWER ON INDICATOR | AMBER. Glows when associated temperature control is turned |
|
| ON. |
W3 | THERMOMETER | Shows temperature in warmer drawer. Must be ordered at time |
| (OPTIONAL ) | of initial equipment build. |
W4 | HUMIDITY CONTROL | Slide control of shutters to control air circulation within the |
|
| warmer drawer. |
5