Honeywell LYNXR Series Troubleshooting Guide, S Y S T E M i n c l u d i n g W i r e l e s s

Models: LYNXR Series LYNXR-EN

1 72
Download 72 pages 18.53 Kb
Page 56
Image 56
Troubleshooting Guide

Troubleshooting Guide

S Y S T E M ( i n c l u d i n g W i r e l e s s )

 

SYMPTOM

 

POSSIBLE CAUSE

 

REMEDY

 

 

 

 

 

 

1.

Transmitter signal

1a.

Transmitter not properly powered.

1a

Check or change transmitter's battery.

 

not received at

1b.

If Transmitter is 5827, House Code not

1b.

Check code switches inside transmitter.

 

control.

 

set in field 24, or transmitter is not set

 

Must match with RF House Code

 

 

 

to same House Code set in that field.

 

programmed.

 

 

1c.

Transmitter is located too far from RF

 

 

 

 

 

receiver.

1c.

Move transmitter or RF receiver.

 

 

1d.

There is metal shielding between

1d.

Check for large metal obstructions, then

 

 

 

transmitter and RF receiver.

 

relocate transmitter if necessary.

 

 

1e.

Transmitter is malfunctioning.

1e.

Verify by activating control with

 

 

 

 

 

another, similar transmitter. If O.K.

 

 

1f.

Transmitter No. (zone) is not

 

now, return defective transmitter.

 

 

 

 

 

 

 

programmed.

1f.

Verify programming.

 

 

 

 

 

 

2.

Transmitter zone

2a.

Transmitter zone type (ZT) is set to 00

2a.

Set ZT to a valid active zone type in

 

number appears

 

(Not Used).

 

field 56.

 

during Transmitter

2b.

Transmitter battery not installed.

2b.

Install proper battery.

 

Sniffer mode, but

2c.

5800 System transmitter not "entered" in

 

does not clear.

2c.

"Enter" unit in field 56 or 83.

 

 

system.

 

 

 

 

 

 

 

 

 

 

 

3.

Low battery message

 

 

 

 

 

on keypad.

 

 

 

 

3a.

"Low Bat" (no zone Nos.)

3a.

System battery is low or missing.

3a.

Replace system battery.

3b.

"Low Bat" + "00".

3b.

Remote RF keypad/button battery is low.

3b.

Replace battery in the RF keypad.

3c.

"Low Bat" + "nn".

3c.

Transmitter for zone “nn” has a low

3c.

Replace the battery in the displayed

 

 

 

battery.

 

transmitter.

 

 

 

 

 

 

4.

Periodic beep(s) from

4a.

System is in Test mode.

4a.

Enter Code + OFF to exit Test mode.

 

keypad.

4b.

A transmitter low battery has occurred

4b.

Enter Code + OFF and replace the

 

 

 

and is displayed.

 

battery.

 

 

4c.

A supervision fault has occurred.

4c.

Check the transmitter indicated.

 

 

 

Restore communication to the receiver

 

 

 

 

 

 

 

4d.

System low battery

 

to cancel the condition.

 

 

4d.

Replace system battery

 

 

 

 

 

 

 

 

 

5.

With 5800 System,

Put control in Test mode. If zone does not

 

 

 

there is no response

respond, try operating the tamper switch or

 

 

 

to a transmitter in

another input to the transmitter.

 

 

 

normal operation,

5a.

If another input causes the zone to be

5a.

Delete input's serial number (not the

 

although zone

 

displayed, the wrong input was "entered"

 

zone), and enter the proper input (see

 

number clears during

 

when programming.

 

field 56).

 

Transmitter Sniffer

5b.

If no response at all from this

 

 

 

mode.

5b.

Determine which transmitter is

 

 

transmitter, this physical transmitter

 

 

 

has not been entered by the system.

 

programmed for this zone and

 

 

 

Transmitter Sniffer display is being

 

reprogram as necessary.

 

 

 

cleared by another unit programmed for

 

 

 

 

 

this zone.

 

 

 

 

 

 

 

 

6.

Nuisance or phantom

6a.

Sensors not properly installed, wired, or

6a.

Check installation to see if in

 

alarm.

 

monitored.

 

accordance with established procedure.

 

 

6b.

Universal transmitter (5817)

6b.

Check programming switches on

 

 

 

programmed wrong.

 

transmitter.

 

 

 

 

 

 

7.

Intrusion alarm for

7a.

Protected door or window opened while

7a.

Check with all occupants of protected

 

no apparent reason.

 

system armed.

 

home.

 

 

7b.

Improper user operation of exit/entry

 

 

 

 

 

delays.

7b.

Check setting of entry and exit delays.

 

 

7c.

Magnets located too far from switches,

7c.

Check all openings for proper switch

 

 

 

and/or doors and windows not properly

 

and magnet orientation.

 

 

 

aligned.

 

 

 

 

 

 

 

 

–56–

Page 56
Image 56
Honeywell LYNXR Series Troubleshooting Guide, S Y S T E M i n c l u d i n g W i r e l e s s, Symptom, Possible Cause