Data Field Descriptions
✻50 |
| If enabled, provides communication delay to the central station and allows | ||
0 | = no dialer delay |
| the subscriber time to avoid a false alarm transmission. Delay does not | |
|
| apply to zone type 6, 7, 8, and 9 alarms, which are always sent as soon as | ||
| 1 | = provide | ||
| they occur. UL installations: must be 0 (no delay) | |||
| when armed away |
| ||
|
|
| ||
|
|
| ||
✻51 | Periodic Test Report | Test report code entered in field ✻64 is sent. | ||
0 | = no test report | 2 = weekly |
| |
|
| |||
| 1 | = once every 24 hrs | 3 = once every 30 days |
|
|
|
| ||
✻52 | First test Report Offset | This is the time to first report from programming or downloading. | ||
0 | = 24 hrs after exit program mode or download |
| ||
|
| |||
| 1 | = 6 hours after exit program mode or download |
| |
| 2 | = 12 hrs after exit program mode or download |
| |
| 3 | = 18 hrs after exit program mode or download |
| |
|
|
| ||
✻53 | Sescoa/Radionics Select | Select 0 for all other formats. | ||
0 | = Radionics |
| ||
|
| |||
| 1 | = SESCOA |
| |
|
|
| ||
✻54 | Lack of Usage Notification | If enabled, notifies the central station if an end user is not operating their | ||
0 | = Disabled | 4 = 90 days | security system by sending a System Inactivity report 654. The report will | |
| be sent only to the Primary phone number and only if Contact ID® format | |||
| 1 | = 1 day | 5 = 180 days | |
| was selected. | |||
| 2 | = 7 days | 6 = 365 days | |
| Note: The report will follow the ✻49 = 0 rules, no matter which selection | |||
| 3 | = 27 days |
| was made in ✻49. |
| Note: There will be no local annunciation indicating that |
| ||
|
| this report has been sent to the Central Station. |
| |
✻58 | RF Jam Detection |
| For Event Logging, Option 2 must be selected. | |
0 | = no jam detection |
| If the control detects an RF jam condition, a “FAULT” message appears for | |
|
| |||
| 1 | = RF jam detection with event logging, but no | zone 90. The Contact ID® code for RF Jam is 344. | |
|
| central station report |
| Note: This feature cannot be used in conjunction with the 5827 wireless |
| 2 | = RF jam detection with event logging and with | keypad. | |
|
| central station report (if trouble/restore report is |
| |
|
| enabled in fields ✻60, ✻71) |
| |
|
|
|
|
|
SYSTEM STATUS AND RESTORE REPORT CODES PROGRAMMING (✻59 – ✻76, & ✻89)
Program Report Codes using the interactive ✻56 Enhanced Zone Programming Mode, or codes can be entered in data fields
With a 3+1 or 4+1 Standard Format: Enter a code in the first box:
With an Expanded or 4+2 Format: Enter codes in both boxes (1st and 2nd digits) for
With ADEMCO Contact ID® Reporting: Enter a digit in the first box to enable the zone to report. Use a different digit for each zone until you have used up available digits. If the number of zones exceeds the number of available digits, begin with digit 1 again. This is an "enabling" code only and is not the actual code sent to the central station office. Entries in the second boxes will be ignored. For system status