Honeywell LYNXR-EN, LYNXR Series setup guide Zone Assignment/Alarm Report Codes For Table

Models: LYNXR Series LYNXR-EN

1 72
Download 72 pages 18.53 Kb
Page 63
Image 63
✻56 ZONE ASSIGNMENT/ALARM REPORT CODES FOR TABLE 1

56 ZONE ASSIGNMENT/ALARM REPORT CODES FOR TABLE 1

Zone No.

Zone Type

Alarm Code

Input Type

Loop Number

Zone Descriptor

1

0

0,0

---

---

 

2

1

1,0

3 (RF)

2

47, 04 (FRONT DOOR)

3

1

1,0

3 (RF)

2

33, 04 (BACK DOOR)

4

3

1,0

3 (RF)

2

80 (WINDOW)

5

10

1,0

3 (RF)

1

56 (MOTION DETECTOR)

26

21

1,0

5 (BR)

3

 

27

22

1,0

5 (BR)

2

 

28

20

1,0

5 (BR)

4

 

29

23

0,0

5 (BR)

1

 

30

21

1,0

5 (BR)

3

 

31

22

1,0

5 (BR)

2

 

32

20

1,0

5 (BR)

4

 

33

23

0,0

5 (BR)

1

 

92

---

1,0

---

---

 

99

6

1,0

---

---

 

NOTE: Zone 1 is a hardwire zone; Zone 2 to 41 are RF zones; Zone 92 is Duress; Zone 99 is keypad panic

56 ZONE ASSIGNMENT/ALARM REPORT CODES FOR TABLE 2

Zone No.

Zone Type

Alarm Code

Input Type

Loop Number

Zone Descriptor

1

0

0,0

---

---

 

 

2

1

1,0

3 (RF)

2

47, 04

(FRONT DOOR)

3

1

1,0

3 (RF)

2

33, 04

(BACK DOOR)

4

1

1,0

3 (RF)

2

48, 04

(GARAGE DOOR))

5

04

1,0

3 (RF)

1

56 (MOTION DETECTOR)

6

9

1,0

3 (RF)

1

22, 02

(SMOKE DETECTOR)

26

21

1,0

5 (BR)

3

 

 

27

22

1,0

5 (BR)

2

 

 

28

20

1,0

5 (BR)

4

 

 

29

23

0,0

5 (BR)

1

 

 

30

21

1,0

5 (BR)

3

 

 

31

22

1,0

5 (BR)

2

 

 

32

20

1,0

5 (BR)

4

 

 

33

23

0,0

5 (BR)

1

 

 

92

---

1,0

---

---

 

 

95

08

1,0

---

---

 

 

96

09

1,0

---

---

 

 

99

07

1,0

---

---

 

 

NOTE: Zone 1 is a hardwire zone; Zone 2 to 41 are RF zones; Zone 92 is Duress; Zone 99 is keypad panic

56 ZONE ASSIGNMENT/ALARM REPORT CODES FOR TABLES 3 & 4

Zone No.

Zone Type

Alarm Code

Input Type

Loop Number

 

Zone Descriptor

1

0

0,0

---

---

 

 

2

1

1,0

3 (RF)

2

47, 04 (FRONT DOOR)

3

1

1,0

3 (RF)

2

33, 04 (BACK DOOR)

4

3

1,0

3 (RF)

2

80

(WINDOW)

5

3

1,0

3 (RF)

2

80

(WINDOW)

6

3

1,0

3 (RF)

2

80

(WINDOW)

7

3

1,0

3 (RF)

2

80

(WINDOW)

8

10

1,0

3 (RF)

1

56

(MOTION DETECTOR)

9

9

1,0

3 (RF)

1

22, 02 (SMOKE DETECTOR)

26

21

1,0

5 (BR)

3

 

 

27

22

1,0

5 (BR)

2

 

 

28

23

0,0

5 (BR)

4

 

 

29

23

0,0

5 (BR)

1

 

 

30

21

1,0

5 (BR)

3

 

 

31

22

1,0

5 (BR)

2

 

 

32

23

0,0

5 (BR)

4

 

 

33

23

0,0

5 (BR)

1

 

 

92

---

1,0

---

---

 

 

99

6

1,0

---

---

 

 

NOTE: Zone 1 is a hardwire zone; Zone 2 to 41 are RF zones; Zone 92 is Duress; Zone 99 is keypad panic

– 63 –

Page 63
Image 63
Honeywell LYNXR-EN, LYNXR Series setup guide Zone Assignment/Alarm Report Codes For Table