Honeywell LYNXR-EN Data Field Descriptions, Defaults where applicable are Indicated in Text

Models: LYNXR Series LYNXR-EN

1 72
Download 72 pages 18.53 Kb
Page 17
Image 17
Data Field Descriptions

Data Field Descriptions

Defaults (where applicable) are Indicated in Text.

The following pages list all data fields in this Control (in numerical order). Use the blank programming form to record the data for this installation. Note that both keypad LEDs flash while in Programming mode.

Note: Entering a number other than the one specified will give unpredictable results.

20

Installer Code

 

 

 

The Installer Code is used to enter the 4-digit Master Security Code. See

Enter 4 digits, 0-9

 

 

 

"Master Code" in the System Operation section for procedure.

 

 

 

 

 

 

 

 

 

 

21

Quick Arm Enable

 

 

If enabled, security code is not required to arm the system. The user

0

= do not allow quick arm

 

 

simply presses and holds down the AWAY or STAY key to arm.

 

 

 

 

 

1

= allow quick arm

 

 

 

 

 

 

 

 

22

Keypad Backlight Timeout

 

This option allows the choice of either always backlighting the keypad or

0

= no timeout; always backlight keys

 

turning the backlighting off after 10 seconds of keypad inactivity.

 

 

 

 

1

= turn backlighting off after inactivity

 

 

 

 

 

 

 

 

23

Forced Bypass

 

 

 

All zones bypassed by this function will be displayed after the bypass is

0

= no forced bypass

 

 

 

initiated.

 

 

 

 

 

 

1

= provide automatic bypass of all open (faulted)

Note: UL installations: must be 0 (no forced bypass)

 

 

zones

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24

RF House ID Code

 

 

The House ID identifies receivers and wireless keypads.

00 = disable all wireless keypad usage

 

If a 5827 Wireless Keypad or 5804BD/5804BDV Transmitter is to be

 

 

used, a House ID Code MUST be entered, and the keypad should be set

 

01-31 = House ID

 

 

 

 

 

 

 

to the same ID.

 

 

 

 

 

 

25

Powerline Carrier Device (X-10) House ID

Powerline Carrier Devices require a House ID. This field identifies this

0 = A 4 = E 8 = I

# + 12 = M

House ID to the Control. The Powerline Carrier Devices are

 

programmed in field 80.

 

1 = B 5 = F 9 = J

# + 13 = N

 

 

 

2 = C 6 = G # + 10 = K # + 14 = O

 

 

3 = D 7 = H # + 11 = L # + 15 = P

 

 

 

 

 

 

 

26

Chime by Zone

 

 

 

This option allows the installer to define the specific zones intended to

0

= no (chimes on fault of any entry/exit or perimeter

chime when faulted while the system is in Chime mode. If enabled, these

 

zones are defined in zone list 3 (see 81 Zone List Menu Mode).

 

 

zone when Chime mode is activated

 

 

 

 

 

 

1

= yes (chimes on fault of those zones assigned to

 

 

 

Zone List 3 when Chime mode on)

 

 

 

 

 

 

27

Real Time Clock Display

 

Refer to the User’s Manual for setting the clock time and date.

0

= do not display the time

 

 

 

 

 

 

 

 

1

= display the time

 

 

 

 

 

 

 

29

Daylight Savings Time Start/End Month

Enter # + 10 for 10, # + 11 for 11, and # + 12 for 12.

0, 0 = no daylight saving time used

 

 

 

 

 

 

1-12 = start month and end month

 

 

 

 

 

30

Daylight Savings Time Start/End Week

Enter the appropriate start and end weekend of the month.

0

= disable

 

4 = fourth weekend

 

 

 

 

 

1

= first weekend of month

5 = last weekend

 

 

2

= second weekend

 

6 = next to last

 

 

3

= third weekend

 

7 = 3rd from last

 

31

Single Alarm Sounding Per Zone

UL installations: must be 0 (no limit)

(per armed period)

 

 

 

This field applies only to burglary zones (zone response types 1-5, 10),

 

 

 

 

and affects long range radio reporting but does not affect central station

 

0

= no limit on alarm sounding per zone

 

 

 

reporting.

 

1

= limit alarm sounding to once per arming period for

 

 

 

 

a given zone

 

 

 

Note: This field applies only to the bell and does not affect keypad

 

LYNXR/LYNXR24 - Applies to Long Range Radio Output if “0”

 

sounds.

 

is selected in field 91

 

 

 

 

 

 

 

 

 

LYNXR-EN- Applies to Long Range Radio Output if Long Range

 

 

Radio is connected to the Trigger Single (Neg.) terminal #8.

 

 

 

 

 

32

Fire Sounder Timeout

 

This Control complies with NFPA requirements for temporal pulse

0

= yes, fire sounder timeout after time programmed in

sounding of fire notification appliances.

 

Temporal pulse sounding for a fire alarm consists of the following:

 

 

field 33

 

 

 

 

 

 

 

 

3 pulses – pause – 3 pulses – pause – 3 pulses. . .

 

1

= no fire sounder timeout; continue sounding until

 

 

 

 

manually turned off

 

 

 

 

 

 

 

 

33

Alarm Bell Timeout

 

 

This field determines whether the external sounder will shut off after

0

= No timeout

2 = 8 min

4 = 16 min

time allowed, or continue until manually turned off.

 

UL installations: must be set for a minimum of 4 min (option 1)

 

1

= 4 min

3 = 12 min

 

 

 

 

 

 

 

 

 

 

34

Exit Delay

 

 

 

The system will wait the time entered before sounding an alarm if the

00-99 = exit delay time in seconds

 

exit door is left open after the system has been armed.

 

 

UL installations: must be set for a maximum of 60 seconds

 

 

 

 

 

 

 

 

 

 

 

 

 

–17–