Honeywell LYNXR Series, LYNXR-EN setup guide Wiring Connections, Wiring Overview

Models: LYNXR Series LYNXR-EN

1 72
Download 72 pages 18.53 Kb
Page 6
Image 6
Wiring Connections

Wiring Connections

Wiring Overview

The following summarizes the connections required. Refer to the Wiring Connections paragraph and the Summary of Connections diagram on the inside back cover when making connections.

HARDWIRE ZONE

Supports 1 EOLR supervised zone using either closed circuit or open circuit sensors.

TWO-WAY VOICE

The LYNXR-EN supports the two-way voice feature/Alarm Audio Verification. The LYNXR and LYNXR24 require the installation of the LYNXAVM.

PHONE LINES

Use either the plug-in jacks or the screw terminals.

EARTH GROUND

See Earth Ground paragraph.

LOCAL SOUNDER DISABLE JUMPER

Remove the shorting jumper (shunt) to disable local sounder, leaving only the external sounder active.

UL NOTE: Do not remove the shorting jumper (the shunt) for UL installations.

LONG RANGE RADIO

Compatible with the ALARMNET 7845C and 7720 Devices.

POWERLINE CARRIER DEVICES

Supports up to 8 Powerline Carrier Devices for turning on/off lights and appliances. Requires the use of an ADEMCO 1332X10 transformer.

MXXXX

K5108

AC TRANSFORMER Use the supplied

ADEMCO 1332X10 9VAC, 15VA Plug-in Transformer (1332CN in Canada).

01009-005-V0

SOUNDERS

The system includes a built-in sounder in the master keypad. If desired, an external bell or piezo sounder can be connected.

Bell: Use a 6-14V bell with maximum current drain of 120mA.

Piezo: Use a 6-14V piezo sounder with maximum current drain of 30mA.

This control complies with NFPA requirements for temporal pulse sounding of fire notification appliances.

Temporal pulse sounding for a fire alarm consists of the following: 3 pulses – pause – 3 pulses – pause – 3 pulses. . .

Wiring Connections

1.Make Earth Ground Connection - The designated earth ground terminal (1) must be terminated in a good earth ground for the lightning transient protective devices in this product to be effective. The following are examples of good earth grounds available at most installations:

Metal Cold Water Pipe - Secure a non-corrosive metal strap (copper is recommended) to the pipe that is electrically connected and secured to which the ground lead.

AC Power Outlet Ground - Available from 3-prong, 120VAC power outlets only. To test the integrity of the ground terminal, use a three-wire circuit tester with neon lamp indicators, such as the UL Listed Ideal Model 61–035, or

equivalent, available at most electrical supply stores.

a.Connect terminal 1 to a good earth ground.

–6–

Page 6
Image 6
Honeywell LYNXR Series, LYNXR-EN setup guide Wiring Connections, Wiring Overview