55 Enabling the 5842 Wireless Dialer

While in Program mode, press 55 to enter Wireless Dialer Programming Feature.

The following explains the 55 prompts in detail. The left two columns identify the prompts and list the available entries for each. The right-most column provides a further explanation of the entries.

Note: You may find it convenient to adjust the volume setting before entering the Programming Mode. This will allow you to clearly hear feedback announcements or system beeps.

 

 

 

Enable the wireless dialer

Enter [1] to enable the 5842 Wireless dialer. Press [] to advance to next

 

Ed

 

[] = continue

field.

 

 

 

 

 

0 = disable

Enter [0] to exit mode. The prompt “55” blinks, indicating the mode is

 

 

 

1 = enable

 

 

 

inactive. Press [] + any field number to go to that field.

 

 

 

 

 

 

 

 

 

 

 

 

Enable trouble reports

If selected, the following 5842 trouble reports will be enabled:

 

Er

 

[] = continue

• Loss of RF link with 5842 Wireless Dialer

 

 

• Tamper at 5842

 

 

[#] = return to previous prompt

 

 

• Low Battery at 5842

 

 

 

0 = disable

 

 

 

• AC loss at 5842 (if supported by the specific wireless dialer being

 

 

 

1 = enable

 

 

 

installed)

 

 

 

 

 

 

 

 

• Line Cut at 5842 (if supported by the specific wireless dialer being

 

 

 

 

installed)

 

 

 

 

Enter [1] to enable 5842 Wireless Dialer trouble reports. Press [] to

 

 

 

 

advance to next field or [#} to return to the previous prompt.

 

 

 

 

 

 

 

 

Response to phone line tamper

Select the Lynx response to detection of a line cut at the 5842 Wireless

 

Ln

 

[] = continue

Dialer.

 

 

If the trouble sounder is enabled the system will sound a trouble event any

 

 

[#] = return to previous prompt

 

 

time the 5842 phone line is cut.

 

 

 

0 = enable trouble sounder

 

 

 

If the alarm sounder is enabled the system will a trouble by day or an

 

 

 

1 = enable alarm sounder

 

 

 

alarm at night in the event that the 5842 phone line is cut.

 

 

 

 

Enter [1] to select alarm or [0] to select trouble in the event of a 5842 line

 

 

 

 

cut. Press [] to advance to next field or [#} to return to the previous

 

 

 

 

prompt.

 

 

 

 

Note: If an X-10 device has been programmed to ZT05 or ZT07 and

 

 

 

 

*55 has been enabled, the device response will be dependent upon

 

 

 

 

the selection made in *55 Field "Ln".

 

 

 

 

 

 

 

 

Enable back-up reporting

Allows Lynx to do back-up reporting for the 5842 wireless dialer. Enter [1]

 

Eb

 

[] = continue

to enable back-up reporting. Refer to the 5842 Wireless Dialer Installation

 

 

guide for additional information.

 

 

[#] = return to previous prompt

 

 

 

 

 

 

0 = disable

Enter [0] to disable back-up reporting. Enter [#} to return to the previous

 

 

 

1 = enable

 

 

 

prompt.

 

 

 

 

Note: Lynx must be connected to the premises phone line via the 5842

 

 

 

 

Wireless Dialer.

 

 

 

 

 

–26–

Page 26
Image 26
Honeywell LYNXR Series, LYNXR-EN Enable the wireless dialer, Enable trouble reports, Response to phone line tamper

LYNXR Series, LYNXR-EN specifications

The Honeywell LYNXR Series, particularly the LYNXR-EN model, represents a pinnacle of advanced security technology designed for residential and small business applications. This all-in-one wireless security system is lauded for its innovative features, ease of use, and powerful performance, making it a top choice among users seeking enhanced security solutions.

One of the standout features of the LYNXR-EN is its user-friendly touchscreen interface. The large, intuitive display allows for straightforward navigation, enabling users to arm or disarm the system, check status, and receive alerts with just a few taps. This ease of use is complemented by programmable quick access keys, which allow users to personalize their experience according to their security requirements.

Additionally, the LYNXR-EN is designed with flexibility in mind. It supports a wide range of wireless sensors and devices, facilitating comprehensive coverage for homes or small businesses. Users can integrate door and window contacts, motion detectors, glass break sensors, and more, ensuring that every entry point is monitored. The system can accommodate up to 48 wireless zones, allowing for extensive security applications without the clutter of wires.

Technologically, the LYNXR-EN leverages advanced RF technology, enhancing the reliability of communication between the panel and sensors. This feature minimizes the risk of interference and ensures consistent performance even in challenging environments. Along with this robust connectivity, the system offers dual-path communication capabilities, enabling both IP and cellular reporting. This redundancy ensures that alerts are promptly sent to the monitoring center and mobile devices, providing peace of mind to users.

Moreover, the LYNXR-EN can be easily integrated with smart home technology. It is compatible with various smart devices, allowing users to control lighting, thermostats, and other home automation features from a single platform. This integration not only enhances convenience but also optimizes energy efficiency.

The LYNXR-EN also includes a built-in battery backup, ensuring that the system remains operational during power outages. This is a crucial feature for maintaining security when it is needed most. Additionally, users can set up customizable alerts and notifications, allowing them to stay informed of any unusual activity in real-time.

In summary, the Honeywell LYNXR Series, especially the LYNXR-EN model, combines advanced technology with user-friendly design to deliver a versatile and robust security solution. Its wireless capabilities, comprehensive sensor support, smart home integration, and reliable communication make it a prominent choice in the ever-evolving realm of security systems.