84 Assign Zone Voice Descriptors

Use this mode to assign voice descriptors for each zone. These are the descriptors that are announced when the system announces any event involving a zone number. Each descriptor can consist of up to 3 words. Press 84 while in Programming mode.

The prompts for 84 are as follows:

84

A01

b

C d

Voice Descriptors ----------------------

Main Menu prompt

Zone Number ---------------------------

for entering the zone number to be programmed

Descriptor 1 -----------------------------

for assigning the first word of this zone’s descriptor

Descriptor 2 -----------------------------

for assigning the second word of this zone’s descriptor

Descriptor 3 -----------------------------

for assigning the third word of this zone’s descriptor

The following explains these prompts in detail. The left two columns identify the prompts and list the available entries. The right-most column provides a further explanation of the entries.

Note: Entering a number other than the one specified will give unpredictable results.

 

 

 

 

Assign zone voice descriptors

Pressing 1 advances to the next prompt below.

 

 

 

 

 

84

 

0 = exit mode

Pressing 0 exits mode, upon which this prompt blinks, indicating the

 

 

 

mode is inactive.

 

 

 

1 = enter mode

 

 

 

 

 

 

 

 

 

 

Zone number

Enter the 2-digit zone number for which this descriptor is being

 

 

 

 

A

zz

 

[] = continue to next prompt (any existing

assigned, then press []. The Voice Descriptor for the selected zone will

 

 

be announced, if it is programmed.

 

 

descriptors will be announced, then

 

 

 

 

descriptor 1 will be repeated)

 

 

 

 

 

00 = exit voice descriptor mode

 

 

 

 

 

 

 

 

 

 

 

Descriptor 1

Enter the first word of the descriptor for the selected zone.

 

b

 

 

vv

 

Enter [#] + 2-digit vocabulary index number of

Use the [6] or [8] key to advance as described.

 

 

To change the entered index number before pressing [6] or [8], simply

 

 

first descriptor word for this zone.

 

 

 

 

6 = accept word and advance to descriptor 2

press [#] + desired 2-digit vocabulary index number.

 

 

 

 

If descriptor 1 is not desired, enter [#] + 99 (blank), then press [8] to

 

 

 

 

(descriptor 2 will be announced)

 

 

 

 

return to zone number prompt.

 

 

 

 

8 = accept word and advance to prompt (A) for

 

 

 

 

 

next zone. Press any other key to repeat the

 

 

 

 

 

selected word.

 

 

 

 

 

 

 

 

 

 

 

Descriptor 2

Enter the second word of the descriptor for the selected zone.

 

 

 

 

C

vv

 

Enter [#] + 2-digit vocabulary index number of

Use the [6] or [8] key to advance as described.

 

 

To change the entered index number before pressing [6] or [8], simply

 

 

second descriptor word for this zone.

 

 

 

 

6 = accept word and advance to descriptor 3

press [#] + desired 2-digit vocabulary index number.

 

 

 

 

If descriptor 2 is not desired, enter [#] + 99 (blank), then press [8] to

 

 

 

 

(descriptor 3 will be announced)

 

 

 

 

return to zone number prompt.

 

 

 

 

8 = accept word and advance to prompt (A) for

 

 

 

 

 

next zone. Press any other key to repeat the

 

 

 

 

 

selected word.

 

 

 

 

 

 

 

 

 

 

 

Descriptor 3

Enter the last word of the descriptor for the selected zone.

 

d

 

 

vv

 

Enter [#] + 2-digit vocabulary index number of

Use the [6] or [8] key to advance as described.

 

 

To change the entered index number before pressing [6] or [8], simply

 

 

third descriptor word for this zone.

 

 

 

 

6 or 8 = accept word and advance to prompt

press [#] + desired 2-digit vocabulary index number.

 

 

 

 

If descriptor 3 is not desired, enter [#] + 99 (blank), then press [8] to

 

 

 

 

(A) for next zone. Zone descriptor will

 

 

 

 

return to zone number prompt.

 

 

 

 

be announced. Press any other key to

 

 

 

 

 

repeat the selected word.

 

 

 

 

 

 

 

–38–

Page 38
Image 38
Honeywell LYNXR Series, LYNXR-EN setup guide Assign Zone Voice Descriptors, Assign zone voice descriptors

LYNXR Series, LYNXR-EN specifications

The Honeywell LYNXR Series, particularly the LYNXR-EN model, represents a pinnacle of advanced security technology designed for residential and small business applications. This all-in-one wireless security system is lauded for its innovative features, ease of use, and powerful performance, making it a top choice among users seeking enhanced security solutions.

One of the standout features of the LYNXR-EN is its user-friendly touchscreen interface. The large, intuitive display allows for straightforward navigation, enabling users to arm or disarm the system, check status, and receive alerts with just a few taps. This ease of use is complemented by programmable quick access keys, which allow users to personalize their experience according to their security requirements.

Additionally, the LYNXR-EN is designed with flexibility in mind. It supports a wide range of wireless sensors and devices, facilitating comprehensive coverage for homes or small businesses. Users can integrate door and window contacts, motion detectors, glass break sensors, and more, ensuring that every entry point is monitored. The system can accommodate up to 48 wireless zones, allowing for extensive security applications without the clutter of wires.

Technologically, the LYNXR-EN leverages advanced RF technology, enhancing the reliability of communication between the panel and sensors. This feature minimizes the risk of interference and ensures consistent performance even in challenging environments. Along with this robust connectivity, the system offers dual-path communication capabilities, enabling both IP and cellular reporting. This redundancy ensures that alerts are promptly sent to the monitoring center and mobile devices, providing peace of mind to users.

Moreover, the LYNXR-EN can be easily integrated with smart home technology. It is compatible with various smart devices, allowing users to control lighting, thermostats, and other home automation features from a single platform. This integration not only enhances convenience but also optimizes energy efficiency.

The LYNXR-EN also includes a built-in battery backup, ensuring that the system remains operational during power outages. This is a crucial feature for maintaining security when it is needed most. Additionally, users can set up customizable alerts and notifications, allowing them to stay informed of any unusual activity in real-time.

In summary, the Honeywell LYNXR Series, especially the LYNXR-EN model, combines advanced technology with user-friendly design to deliver a versatile and robust security solution. Its wireless capabilities, comprehensive sensor support, smart home integration, and reliable communication make it a prominent choice in the ever-evolving realm of security systems.