Honeywell LYNXR Series, LYNXR-EN Wiring Connections, Of This System, Replace Every Four Years

Models: LYNXR Series LYNXR-EN

1 72
Download 72 pages 18.53 Kb
Page 8
Image 8
OF THIS SYSTEM

Wiring Connections

WARNING:

 

 

ALL OUTPUT CIRCUITS ARE POWER LIMITED.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TO PREVENT RISK OF SHOCK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DISCONNECT TELEPHONE LINE

 

 

 

 

 

AAV / LRR

 

 

 

 

 

AT TELECOM JACK BEFORE

 

 

 

 

 

 

 

TRIGGER

 

 

 

 

 

SERVICING THIS UNIT.

 

 

 

 

 

(LYNXR/LYNR24)

 

 

 

 

 

EARTH

 

 

 

 

 

 

 

LRR

 

 

 

 

 

 

 

 

 

 

 

 

TRIGGER

 

 

 

 

 

GROUND

PHONE

 

 

ZONE (LYNXR-EN) SOUNDERS

PLCD

 

AC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

RJ11

POS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

JACK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TIP

RING

TIP

RING

(+)

( )

 

( )

(+)

( )

(+)

DATA SYNC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HARD

 

 

 

 

 

OUT

IN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWERLINE DEVICESCARRIER

 

 

TO

INCOMING

 

 

 

 

 

WIRED

 

 

 

 

 

 

 

 

 

 

 

 

ZONE

 

 

 

 

 

 

 

 

 

HANDSET

PHONE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PHONE

LINE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LINE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOCAL SOUNDER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DISABLE SHUNT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REMOVE TO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DISABLE

 

TRIGGER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INCOMING

 

SIGNAL

 

 

 

 

 

 

1332/

 

 

 

 

 

 

 

 

(NEG)

 

 

 

 

 

 

 

 

 

 

 

 

 

TELEPHONE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1332X10/

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LINE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1332CN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EARTH

 

PREMISES

 

PIEZO

 

 

 

 

 

PLUG-IN

 

 

 

 

 

 

 

 

TRANSFORMER

 

 

GROUND

TELEPHONE

 

 

 

 

 

 

 

BELL

 

 

 

9VAC, 15VA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2k OHMS

 

6-14VDC

 

 

 

 

 

 

 

 

AC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EOLR

 

30mA max.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6-14VDC

 

 

 

 

 

AC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

120mA max.

 

 

 

 

 

 

 

THE LYNX SERIES CONTROLS ARE

 

 

 

 

 

(e.g. WAVE2EX)

 

 

 

 

 

 

SYNC

EQUIPPED WITH AN INTEGRAL

 

 

WEEKLY TESTING IS

 

 

 

 

 

 

 

 

 

 

 

 

 

RECHARGEABLE BATTERY PACK.

 

 

REQUIRED TO ENSURE

 

 

 

 

 

 

 

 

 

 

 

 

COM

LYNXR:

P/N LYNXRCHKIT-SC

 

 

PROPER OPERATION

 

 

 

 

 

 

 

 

 

 

 

 

 

LYNXR24:

P/N LYNXRCHKIT-HC

 

 

OF THIS SYSTEM

 

 

 

 

 

 

 

 

 

 

 

DATA

LYNXR-EN:

P/N LYNXRCHKIT-SC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OR

 

 

 

 

 

NOTE

 

 

 

1332X10

 

P/N LYNXRCHKIT-HC

 

 

 

 

 

 

 

 

 

 

 

 

 

USE ONLY 1332/1332X10 OR 1332CN

 

 

 

REPLACE EVERY FOUR YEARS

 

 

 

 

 

 

 

 

 

ONLY

 

 

 

 

 

TRANSFORMERS PROVIDED

 

 

CONNECTIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01009-009-V0

–8–